Back to Search Start Over

Introducing a Novel Method of Patella Tendon Defunctioning using Suture Anchors after a Tibial Tuberosity Avulsion Repair: Report of Three Cases

Authors :
Ejy Cheong
Ltj Tan
Source :
Malaysian Orthopaedic Journal, Malaysian Orthopaedic Journal, Vol 15, Iss 2, Pp 159-162 (2021)
Publication Year :
2021
Publisher :
Malaysian Orthopaedic Association, 2021.

Abstract

Tibial tuberosity avulsion injuries are rare and result from direct trauma to the tibial tuberosity or forceful and repetitive contraction of the quadriceps muscles. In this case series, we describe a novel method of defunctioning the patella tendon using a suture anchor after a tibial tuberosity avulsion fracture repair was performed. We present three consecutive patients with tibial tuberosity avulsion fractures who were treated by the same surgeon using the technique described. Pre and post-operative range of motion of the knee joint were then reviewed retrospectively. All patients achieved pre-injury range of motion within three months post-operatively. In conclusion, defunctioning the patellar tendon with a suture anchor is a reliable and reproducible technique. The new technique yielded excellent functional outcomes which allowed patients to regain their pre-injury range of motion and the strength of the construct allows early range of motion.

Details

Language :
English
ISSN :
2232111X and 19852533
Volume :
15
Issue :
2
Database :
OpenAIRE
Journal :
Malaysian Orthopaedic Journal
Accession number :
edsair.doi.dedup.....5d5f490e19b73e1fd0594c5f756df4c9