Back to Search Start Over

Multiparametric MRI Apparent Diffusion Coefficient (ADC) accuracy in diagnosing clinically significant prostate cancer

Authors :
Pietro Pepe
Antonio Galia
Maria Gabriella Sabini
Giandomenico Priolo
Giorgio Ivan Russo
Filippo Fraggetta
L. M. Valastro
Michele Pennisi
Davide D’Urso
Antonio Garufi
Source :
In vivo (Athens) 31 (2017): 415–418. doi:10.21873/invivo.11075, info:cnr-pdr/source/autori:Pepe Pietro 1, D'urso Davide 2, Garufi Antonio 3, Priolo Giandomenico 3, Pennisi Michele 1, Russo Giorgio 4, Sabini Maria Gabriella 2, Valastro Lucia Maria 2, Galia Antonio 5, Fraggetta Filippo 5/titolo:Multiparametric MRI Apparent Diffusion Coefficient (ADC) accuracy in diagnosing clinically significant prostate cancer/doi:10.21873%2Finvivo.11075/rivista:In vivo (Athens)/anno:2017/pagina_da:415/pagina_a:418/intervallo_pagine:415–418/volume:31
Publication Year :
2017
Publisher :
In vivo, Athens , Grecia, 2017.

Abstract

AIM: To evaluate the accuracy of multiparametric magnetic resonance imaging apparent diffusion coefficient (mpMRI ADC) in the diagnosis of clinically significant prostate cancer (PCa). PATIENTS AND METHODS: From January 2016 to December 2016, 44 patients who underwent radical prostatectomy for PCa and mpMRI lesions suggestive of cancer were retrospectively evaluated at definitive specimen. The accuracy of suspicious mpMRI prostate imaging reporting and data system (PI-RADS >=3) vs. ADC values in the diagnosis of Gleason score >=7 was evaluated. RESULTS: Receiver operating characteristics (ROC) curve analysis gave back an ADC threshold of 0.747×10-3 mm2/s to separate between Gleason Score 6 and >=7. The diagnostic accuracy of ADC value (cut-off 0.747×10-3 mm2/s) vs. PI-RADS score >=3 in diagnosing PCa with Gleason score >=7 was equal to 84% vs. 63.6% with an area under the curve (AUC) ROC of 0.81 vs. 0.71, respectively. CONCLUSION: ADC evaluation could support clinicians in decision making of patients with PI-RADS score

Details

Language :
English
Database :
OpenAIRE
Journal :
In vivo (Athens) 31 (2017): 415–418. doi:10.21873/invivo.11075, info:cnr-pdr/source/autori:Pepe Pietro 1, D'urso Davide 2, Garufi Antonio 3, Priolo Giandomenico 3, Pennisi Michele 1, Russo Giorgio 4, Sabini Maria Gabriella 2, Valastro Lucia Maria 2, Galia Antonio 5, Fraggetta Filippo 5/titolo:Multiparametric MRI Apparent Diffusion Coefficient (ADC) accuracy in diagnosing clinically significant prostate cancer/doi:10.21873%2Finvivo.11075/rivista:In vivo (Athens)/anno:2017/pagina_da:415/pagina_a:418/intervallo_pagine:415–418/volume:31
Accession number :
edsair.doi.dedup.....5e3e30d9bc5c0de0845cba1da5cd17d3
Full Text :