Back to Search
Start Over
Assessment of Interrater and Intrarater Reliability of Cervical Range of Motion (CROM) Goniometer
- Source :
- BioMed Research International, BioMed Research International, Vol 2020 (2020)
- Publication Year :
- 2020
- Publisher :
- Hindawi Limited, 2020.
-
Abstract
- Purpose. The current study was designed to assess interrater and intrarater validity of cervical range of motion measurements performed with a CROM goniometer. Material and Methods. The study involved 95 healthy university students (31 males and 64 females) aged 20-24 years. Two examiners performed measurements of cervical range of motion using a CROM goniometer. The same subjects were examined again after two weeks, in the same conditions. The results acquired by one rater during the first and the second examination were compared for reproducibility, while the results obtained by the two examiners were compared to assess validity and reliability of the tool. Cronbach’s alpha was applied to determine intrarater reliability, and the values of correlations were used to assess the interrater agreement. Results. Analysis of the results showed both intrarater and interrater agreement in all the measures of cervical range of motion. The highest intrarater and interrater concordance was observed in the measure of extension. Intrarater agreement for Examiner 1 was reflected by Cronbach’s alpha=0.85, and for Examiner 2 by Cronbach’s alpha=0.89. As for the interrater agreement in the measure of extension, the value of correlation in both the first and the second measurement amounted to r=0.89. Conclusions. Measurements performed with the CROM goniometer show interrater and intrarater agreement in assessments of cervical range of motion. The CROM goniometer can be recommended for use in daily clinical practice.
- Subjects :
- Adult
Male
Article Subject
Concordance
Validity
General Biochemistry, Genetics and Molecular Biology
Young Adult
03 medical and health sciences
0302 clinical medicine
Cronbach's alpha
Humans
Medicine
Range of Motion, Articular
Observer Variation
Orthodontics
030222 orthopedics
Reproducibility
Arthrometry, Articular
General Immunology and Microbiology
business.industry
General Medicine
Intra-rater reliability
Inter-rater reliability
Goniometer
Cervical Vertebrae
Female
Range of motion
business
Neck
030217 neurology & neurosurgery
Research Article
Subjects
Details
- ISSN :
- 23146141 and 23146133
- Volume :
- 2020
- Database :
- OpenAIRE
- Journal :
- BioMed Research International
- Accession number :
- edsair.doi.dedup.....60fdf3d39d8dc79d3cb8e53fdf602924
- Full Text :
- https://doi.org/10.1155/2020/8908035