Predictors of atrial mechanical sensing and atrioventricular synchrony with a leadless ventricular pacemaker: Results from the MARVEL 2 Study
- Source :
- Garweg, C, Khelae, S K, Steinwender, C, Chan, J Y S, Ritter, P, Johansen, J B, Sagi, V, Epstein, L M, Piccini, J P, Pascual, M, Mont, L, Willems, R, Sheldon, T, Splett, V, Stromberg, K, Wood, N & Chinitz, L 2020, ' Predictors of atrial mechanical sensing and atrioventricular synchrony with a leadless ventricular pacemaker : Results from the MARVEL 2 Study ', Heart Rhythm, vol. 17, no. 12, pp. 2037-2045 . https://doi.org/10.1016/j.hrthm.2020.07.024
- Publication Year :
- 2020
- Publisher :
- ELSEVIER SCIENCE INC, 2020.
-
Abstract
- BACKGROUND: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%. Previously, low amplitude of the Micra-sensed atrial signal (A4) was observed to be a factor of low AVS. OBJECTIVE: The purpose of this study was to identify predictors of A4 amplitude and high AVS. METHODS: We analyzed 64 patients enrolled in MARVEL 2 who had visible P waves on electrocardiogram for assessing A4 amplitude and 40 patients with third-degree AV block for assessing AVS at rest. High AVS was defined as >90% correct atrial-triggered ventricular pacing. The association between clinical factors and echocardiographic parameters with A4 amplitude was investigated using a multivariable model with lasso variable selection. Variables associated with A4 amplitude together with premature ventricular contraction burden, sinus rate, and sinus rate variability (standard deviation of successive differences of P-P intervals [SDSD]) were assessed for association with AVS. RESULTS: In univariate analysis, low A4 amplitude was inversely related to atrial function assessed by E/A ratio and e'/a' ratio, and was directly related to atrial contraction excursion (ACE) and atrial strain (Ɛa) on echocardiography (all P ≤.05). The multivariable lasso regression model found coronary artery bypass graft history, E/A ratio, ACE, and Ɛa were associated with low A4 amplitude. E/A ratio and SDSD were multivariable predictors of high AVS, with >90% probability if E/A
- Subjects :
- Adult
Male
Pacemaker, Artificial
medicine.medical_specialty
Heart Ventricles
030204 cardiovascular system & hematology
Ventricular contraction
Electrocardiography
Young Adult
03 medical and health sciences
Atrioventricular synchrony
0302 clinical medicine
Lasso regression
Physiology (medical)
Internal medicine
medicine
Humans
Heart Atria
Prospective Studies
cardiovascular diseases
030212 general & internal medicine
Multivariable model
Atrioventricular Block
Aged
Aged, 80 and over
Univariate analysis
business.industry
Predictors
Cardiac Pacing, Artificial
Middle Aged
Ventricular pacemaker
Atrial strain
medicine.anatomical_structure
Amplitude
Echocardiography
Leadless pacing
Cardiology
cardiovascular system
Female
Cardiology and Cardiovascular Medicine
business
Micra transcatheter pacemaker
Follow-Up Studies
Artery
Atrioventricular block
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Garweg, C, Khelae, S K, Steinwender, C, Chan, J Y S, Ritter, P, Johansen, J B, Sagi, V, Epstein, L M, Piccini, J P, Pascual, M, Mont, L, Willems, R, Sheldon, T, Splett, V, Stromberg, K, Wood, N & Chinitz, L 2020, ' Predictors of atrial mechanical sensing and atrioventricular synchrony with a leadless ventricular pacemaker : Results from the MARVEL 2 Study ', Heart Rhythm, vol. 17, no. 12, pp. 2037-2045 . https://doi.org/10.1016/j.hrthm.2020.07.024
- Accession number :
- edsair.doi.dedup.....61828dd5790bd597e5ea87e24fa2d94e
- Full Text :
- https://doi.org/10.1016/j.hrthm.2020.07.024