Back to Search
Start Over
Semi-automatic attenuation of cochlear implant artifacts for the evaluation of late auditory evoked potentials
- Source :
- Hearing Research. 284:6-15
- Publication Year :
- 2012
- Publisher :
- Elsevier BV, 2012.
-
Abstract
- Electrical artifacts caused by the cochlear implant (CI) contaminate electroencephalographic (EEG) recordings from implanted individuals and corrupt auditory evoked potentials (AEPs). Independent component analysis (ICA) is efficient in attenuating the electrical CI artifact and AEPs can be successfully reconstructed. However the manual selection of CI artifact related independent components (ICs) obtained with ICA is unsatisfactory, since it contains expert-choices and is time consuming. We developed a new procedure to evaluate temporal and topographical properties of ICs and semi-automatically select those components representing electrical CI artifact. The CI Artifact Correction (CIAC) algorithm was tested on EEG data from two different studies. The first consists of published datasets from 18 CI users listening to environmental sounds. Compared to the manual IC selection performed by an expert the sensitivity of CIAC was 91.7% and the specificity 92.3%. After CIAC-based attenuation of CI artifacts, a high correlation between age and N1–P2 peak-to-peak amplitude was observed in the AEPs, replicating previously reported findings and further confirming the algorithm's validity. In the second study AEPs in response to pure tone and white noise stimuli from 12 CI users that had also participated in the other study were evaluated. CI artifacts were attenuated based on the IC selection performed semi-automatically by CIAC and manually by one expert. Again, a correlation between N1 amplitude and age was found. Moreover, a high test–retest reliability for AEP N1 amplitudes and latencies suggested that CIAC-based attenuation reliably preserves plausible individual response characteristics. We conclude that CIAC enables the objective and efficient attenuation of the CI artifact in EEG recordings, as it provided a reasonable reconstruction of individual AEPs. The systematic pattern of individual differences in N1 amplitudes and latencies observed with different stimuli at different sessions, strongly suggests that CIAC can overcome the electrical artifact problem. Thus CIAC facilitates the use of cortical AEPs as an objective measurement of auditory rehabilitation.
- Subjects :
- Male
medicine.medical_specialty
Computer science
Speech recognition
medicine.medical_treatment
Deafness
Audiology
Electroencephalography
Correlation
Cochlear implant
medicine
Humans
Aged
Auditory Cortex
Artifact (error)
medicine.diagnostic_test
Attenuation
White noise
Middle Aged
Independent component analysis
Sensory Systems
Cochlear Implants
Acoustic Stimulation
Evoked Potentials, Auditory
Female
Semi automatic
Artifacts
Algorithms
Subjects
Details
- ISSN :
- 03785955
- Volume :
- 284
- Database :
- OpenAIRE
- Journal :
- Hearing Research
- Accession number :
- edsair.doi.dedup.....62ce1c1e920649a93f14d6c77db9cdd3
- Full Text :
- https://doi.org/10.1016/j.heares.2011.12.010