A high-throughput microfluidic device to study neurite response to growth factor gradients
- Source :
- Prof. Kamm via Angie Locknar
- Publication Year :
- 2010
- Publisher :
- Royal Society of Chemistry, 2010.
-
Abstract
- Studying neurite guidance by diffusible or substrate bound gradients is challenging with current techniques. In this study, we present the design, fabrication and utility of a microfluidic device to study neurite guidance under chemogradients. Experimental and computational studies demonstrated the establishment of a steep gradient of guidance cue within 30 min and stable for up to 48 h. The gradient was found to be insensitive to external perturbations such as media change and movement of device. The effects of netrin-1 (0.1–10 µg mL−1) and brain pulp (0.1 µL mL−1) were evaluated for their chemoattractive potential on neurite turning, while slit-2 (62.5 or 250 ng mL−1) was studied for its chemorepellant properties. Hippocampal or dorsal root ganglion (DRG) neurons were seeded into a micro-channel and packed onto the surface of a 3D collagen gel. Neurites grew into the matrix in three dimensions, and a gradient of guidance cue was created orthogonal to the direction of neurite growth to impact guidance. The average turning angle of each neurite was measured and averaged across multiple devices cultured under similar conditions to quantify the effect of guidance cue gradient. Significant positive turning towards gradient was measured in the presence of brain pulp and netrin-1 (1 µg mL−1), relative to control cultures which received no external guidance cue (p < 0.001). Netrin-1 released from transfected fibroblasts had the most positive turning effect of all the chemoattractive cues tested (p < 0.001). Slit-2 exhibited strong chemorepellant characteristics on both hippocampal and DRG neurite guidance at 250 ng mL−1 concentration. Slit-2 also showed similar behavior on DRG neuron invasion into 3D collagen gel (p < 0.01 relative to control cultures). Taken together, the results suggest the utility of this microfluidic device to generate stable chemogradients for studying neurobiology, cell migration and proliferation, matrix remodeling and co-cultures with other cell lines, with potential applications in cancer biology, tissue engineering and regenerative medicine.<br />Seoul R&BD Support Center (program PA090930)
- Subjects :
- Neurite
medicine.medical_treatment
Biomedical Engineering
Bioengineering
Nerve Tissue Proteins
Matrix (biology)
Hippocampal formation
Biochemistry
Cell Line
Dorsal root ganglion
Tissue engineering
Cell Movement
Ganglia, Spinal
Netrin
medicine
Neurites
Animals
Humans
Dimethylpolysiloxanes
Nerve Growth Factors
Neurons
Chemistry
Growth factor
Tumor Suppressor Proteins
Cell migration
General Chemistry
Microfluidic Analytical Techniques
Netrin-1
Coculture Techniques
Nylons
medicine.anatomical_structure
Biophysics
Intercellular Signaling Peptides and Proteins
Collagen
Biomedical engineering
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Prof. Kamm via Angie Locknar
- Accession number :