Back to Search
Start Over
Use of Fast HPLC Multiple Reaction Monitoring Cubed for Endogenous Retinoic Acid Quantification in Complex Matrices
- Source :
- Analytical Chemistry. 87:3222-3230
- Publication Year :
- 2015
- Publisher :
- American Chemical Society (ACS), 2015.
-
Abstract
- Retinoic acid (RA), an essential active metabolite of vitamin A, controls numerous physiological processes. In addition to the analytical challenges owing to its geometric isomers, low endogenous abundance, and often localized occurrence, nonspecific interferences observed during liquid chromatography (LC) multiple reaction monitoring (MRM) quantification methods have necessitated lengthy chromatography to obtain accurate quantification free of interferences. We report the development and validation of a fast high performance liquid chromatography (HPLC) multiplexing multiple reaction monitoring cubed (MRM(3)) assay for selective and sensitive quantification of endogenous RA from complex matrices. The fast HPLC separation was achieved using an embedded amide C18 column packed with 2.7 μm fused-core particles which provided baseline resolution of endogenous RA isomers (all-trans-RA, 9-cis-RA, 13-cis-RA, and 9,13-di-cis-RA) and demonstrated significant improvements in chromatographic efficiency compared to porous particle stationary phases. Multiplexing technology further enhanced sample throughput by a factor of 2 by synchronizing parallel HPLC systems to a single mass spectrometer. The fast HPLC multiplexing MRM(3) assay demonstrated enhanced selectivity for endogenous RA quantification in complex matrices and had comparable analytical performance to robust, validated LC-MRM methodology for RA quantification. The quantification of endogenous RA using the described assay was validated on a number of mouse tissues, nonhuman primate tissues, and human plasma samples. The combined integration of fast HPLC, MRM(3), and multiplexing yields an analysis workflow for essential low-abundance endogenous metabolites that has enhanced selectivity in complex matrices and increased throughput that will be useful in efficiently interrogating the biological role of RA in larger study populations.
- Subjects :
- Detection limit
Time Factors
Chromatography
Resolution (mass spectrometry)
Selected reaction monitoring
Retinoic acid
Tretinoin
Mass spectrometry
High-performance liquid chromatography
Mass Spectrometry
Article
Analytical Chemistry
Mice
chemistry.chemical_compound
Isomerism
chemistry
Limit of Detection
Animals
Humans
Chromatography, High Pressure Liquid
Active metabolite
Cis–trans isomerism
Subjects
Details
- ISSN :
- 15206882 and 00032700
- Volume :
- 87
- Database :
- OpenAIRE
- Journal :
- Analytical Chemistry
- Accession number :
- edsair.doi.dedup.....645f9af73363088bd5980452b5f8d4b4
- Full Text :
- https://doi.org/10.1021/ac504597q