Back to Search
Start Over
Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging
- Source :
- The Quarterly Journal of Nuclear Medicine and Molecular Imaging. 61
- Publication Year :
- 2017
- Publisher :
- Edizioni Minerva Medica, 2017.
-
Abstract
- Background IQ SPECT consists of a new pinhole-like collimator, cardio-centric acquisition, and advanced 3D iterative SPECT reconstruction. The aim of this paper was to compare diagnostic accuracy and functional parameters obtained with IQ SPECT versus conventional SPECT in patients undergoing myocardial perfusion scintigraphy with adenosine stress and at rest. Methods Eight patients with known or suspected coronary artery disease underwent [99mTc] tetrofosmin gated SPECT. Acquisition was performed on a Symbia T6 equipped with IQ SPECT and on a conventional gamma camera system. Gated SPECT data were used to calculate functional parameters. Scores analysis was performed on a 17-segment model. Coronary angiography and clinical follow-up were considered as diagnostic reference standard. Results Mean acquisition time was 4 minutes with IQ SPECT and 21 minutes with conventional SPECT. Agreement degree on the diagnostic accuracy between both systems was 0.97 for stress studies, 0.91 for rest studies and 0.96 for both studies. Perfusion abnormalities scores obtained by using IQ SPECT and conventional SPECT were not significant different: SSS, 9.7±8.8 and 10.1±6.4; SRS, 7.1±6.1 and 7.5±7.3; SDS, 4.0±6.1 and 3.9±4.3, respectively. However, a significant difference was found in functional parameters derived from IQ SPECT and conventional SPECT both after stress and at rest. Mean LVEF was 8% lower using IQ SPECT. Differences in LVEF were found in patients with normal LVEF and patients with reduced LVEF. Conclusions Functional parameters using accelerated cardiac acquisition with IQ SPECT are significantly different to those obtained with conventional SPECT, while agreement for clinical interpretation of myocardial perfusion scintigraphy with both techniques is high.
- Subjects :
- Adult
Male
medicine.medical_specialty
Time Factors
Rest
Gated SPECT
Coronary Artery Disease
Sensitivity and Specificity
law.invention
Coronary artery disease
Myocardial perfusion imaging
Imaging, Three-Dimensional
Stress, Physiological
law
medicine
Humans
Radiology, Nuclear Medicine and imaging
Aged
Gamma camera
Aged, 80 and over
Tomography, Emission-Computed, Single-Photon
Ejection fraction
medicine.diagnostic_test
business.industry
Myocardial Perfusion Imaging
Heart
Middle Aged
medicine.disease
SSS
Female
Tomography
Radiology
business
Nuclear medicine
Perfusion
Subjects
Details
- ISSN :
- 18271936 and 18244785
- Volume :
- 61
- Database :
- OpenAIRE
- Journal :
- The Quarterly Journal of Nuclear Medicine and Molecular Imaging
- Accession number :
- edsair.doi.dedup.....649d9b608dbed169625165d9fab513c3
- Full Text :
- https://doi.org/10.23736/s1824-4785.16.02703-5