Back to Search Start Over

Binocular non-stereoscopic cues can deceive clinical tests of stereopsis

Authors :
Samantha Wenyan Chan
Dennis M. Levi
Bahia Guellaï
Adrien Chopin
Daphne Bavelier
Université de Genève = University of Geneva (UNIGE)
University of California [Berkeley] (UC Berkeley)
University of California (UC)
Laboratoire Éthologie Cognition Développement (LECD)
Université Paris Nanterre (UPN)
Source :
Chopin, Adrien; Chan, Samantha Wenyan; Guellai, Bahia; Bavelier, Daphné; & Levi, Dennis Michael. (2019). Binocular non-stereoscopic cues can deceive clinical tests of stereopsis.. Scientific reports, 9(1), 5789. doi: 10.1038/s41598-019-42149-2. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/7qf2m4z8, Scientific reports, vol 9, iss 1, Scientific Reports, Scientific Reports, Vol. 9, No 5789 (2019), Scientific Reports, Vol 9, Iss 1, Pp 1-10 (2019), Scientific Reports, 2019, 9, pp.5789. ⟨10.1038/s41598-019-42149-2⟩
Publication Year :
2019
Publisher :
eScholarship, University of California, 2019.

Abstract

Stereoscopic vision plays a critical role in visual perception; however, it is difficult to assess. In clinical settings, stereoacuity is assessed with clinical stereotests. Observers can use monocular cues to deceive some of the most common stereotests, such as the Titmus test. The Randot test has been found free of monocular cues, and here we confirm that result by testing observers under monocular viewing. However, there is a common misconception that only monocular cues can be used to deceive stereotests. Here we demonstrate that binocular non-stereoscopic cues can also be used to pass the Randot, by testing participants with the test rotated, a condition that abolishes stereopsis, and comparing the performance to a monocular viewing condition. We also assessed the Random Dot Butterfly test and discovered considerable amounts of non-stereoscopic cues, including binocular cues in the Circles that can be used to deceive the test. Participants with amblyopia had more difficulty using non-stereoscopic cues than neurotypical observers. We gathered normal-viewing Randot stereoacuities for 110 participants (90 neurotypical and 20 with amblyopia) and compared them to psychophysical stereoacuities (our gold standard). The Randot test showed low positive normalized predictive values for detecting stereoblindness. It could perfectly detect stereo-impairment but with a low sensitivity.

Details

Language :
English
ISSN :
20452322
Database :
OpenAIRE
Journal :
Chopin, Adrien; Chan, Samantha Wenyan; Guellai, Bahia; Bavelier, Daphné; & Levi, Dennis Michael. (2019). Binocular non-stereoscopic cues can deceive clinical tests of stereopsis.. Scientific reports, 9(1), 5789. doi: 10.1038/s41598-019-42149-2. UC Berkeley: Retrieved from: http://www.escholarship.org/uc/item/7qf2m4z8, Scientific reports, vol 9, iss 1, Scientific Reports, Scientific Reports, Vol. 9, No 5789 (2019), Scientific Reports, Vol 9, Iss 1, Pp 1-10 (2019), Scientific Reports, 2019, 9, pp.5789. ⟨10.1038/s41598-019-42149-2⟩
Accession number :
edsair.doi.dedup.....6528501f304142c13ac5ddbb30858c7f
Full Text :
https://doi.org/10.1038/s41598-019-42149-2.