- Purpose To evaluate the diagnostic accuracy of circumpapillary retinal nerve fiber layer (cRNFL), optic nerve head, and macular parameters for the detection of glaucoma using Heidelberg Spectralis OCT (Heidelberg Engineering, Inc., Heidelberg, Germany). Design Cross-sectional study. Participants Participants of the Northern Ireland Cohort for the Longitudinal Study of Ageing with a vertical cup-to-disc ratio of 0.7 or more, vertical cup-to-disc ratio asymmetry of 0.2 or more, vertical neuroretinal rim ratio of 0.1 or less, intraocular pressure of 25 mmHg or more, or a combination thereof were invited to the study. Methods Participants underwent clinical examination by a masked glaucoma expert and full-threshold visual field testing to define glaucoma. Five index tests were performed: (1) standard cRNFL thickness, (2) macular Early Treatment Diabetic Retinopathy Study (ETDRS) scans, (3) macular posterior pole asymmetry analysis (PPAA) scans, (4) Bruch's membrane opening minimum rim width (BMO MRW), and (5) Glaucoma Module Premium Edition (GMPE) cRNFL Anatomic Positioning System (APS) scans. We analyzed the eye with more advanced disease per participant. Main Outcome Measures Analysis of receiver operating characteristic (ROC) curve; area under the ROC curve (AUC); and partial AUC (pAUC) at specificity of 0.80 to 1, 0.90 to 1, and 0.95 to 1. Sensitivity at 0.95 specificity and specificity at 0.95 sensitivity were reported. Primary analysis included all available scans. Results One hundred twenty-eight eyes from 128 participants were enrolled (52 eyes with perimetric glaucoma and 76 eyes without glaucoma). One hundred thirteen standard cRNFL thickness scans; 107 GMPE cRNFL APS 3.5-mm, 4.1-mm, and 4.7-mm scans; 107 BMO-MRW scans; 98 ETDRS scans; and 97 PPAA scans were available. Standard cRNFL mean global thickness showed highest AUC (0.869; 95% confidence interval [CI], 0.800–0.938) and the highest pAUC at specificity of 0.80 to 1 (0.815; 95% CI, 0.742–0.887), at specificity of 0.90 to 1 (0.794; 95% CI, 0.713–0.875), and at specificity of 0.95 to 1 (0.765; 95% CI, 0.696–0.861). Standard cRNFL mean global thickness scans provided the highest sensitivity at 0.95 specificity (0.630), whereas ETDRS mGCL outer inferior sector provided the highest specificity at 0.95 sensitivity (0.522). Conclusions Macular and optic nerve head OCT parameters were not better than cRNFL measurements to diagnose glaucoma in this population.
- Subjects :
- Male
Retinal Ganglion Cells
medicine.medical_specialty
Intraocular pressure
genetic structures
Optic Disk
Population
Posterior pole
Glaucoma
01 natural sciences
03 medical and health sciences
Nerve Fibers
0302 clinical medicine
Ophthalmology
medicine
Humans
Macula Lutea
0101 mathematics
education
Intraocular Pressure
Dioptre
Aged
Retrospective Studies
education.field_of_study
Receiver operating characteristic
business.industry
010102 general mathematics
General Medicine
Diabetic retinopathy
Middle Aged
medicine.disease
eye diseases
3. Good health
Cross-Sectional Studies
ROC Curve
030221 ophthalmology & optometry
Optic nerve
Female
sense organs
business
Tomography, Optical Coherence
Follow-Up Studies
Subjects
Details
- ISSN :
- 25894196
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Ophthalmology Glaucoma
- Accession number :
- edsair.doi.dedup.....66506e31deb2e5368bd95986b59e2808
- Full Text :
- https://doi.org/10.1016/j.ogla.2019.06.003