Abstract
- Background The treatment of vertical femoral neck fractures (vFNFs) in young patients remains challenging, with a high complication rate by using traditional techniques. The use of cannulated screws (CSs) combined with a buttress plate represents an alternative approach for treating vFNFs. However, the biomechanical influence of the use or non-use of the proximal screws of buttress plates on vFNFs stability remains unclear. This study aims to analyse the biomechanics of buttress plate fixation with or without the use of proximal screws through finite element analysis (FEA) to further understand this approach. Methods We built five vFNFs (Pauwels angle 70°) finite element models treated using three cannulated screws (CS group) or three cannulated screws plus a locking buttress plate (buttress group). In the buttress group, use or non-use of proximal screws was carried out on two types of plates (4-hole & 6-hole). The following seven parameters were analysed to compare biomechanical properties of the five models: the stiffness; the maximal stress of the plate system (plate and screws), CSs and bone (MPS, MCS, MBS); the maximal displacement of internal fixations (plate system & CSs) and bone (MIFD, MBD); and the maximal relative displacement of interfragments (MID). Results Compared with CS model, the buttress models exhibited improved biomechanical properties, with increased stiffness and decreased MCS, MBS, MIFD, MBD and MID. The models fixed using buttress plates combined with a proximal screw showed greater stiffness (+ 3.75% & + 8.31% vs + 0.98% & + 4.57%) and MPS (795.6 & 947.2 MPa vs 294.9 & 556.2 MPa) values, and smaller MCS, MBS, MIFD, MBD and MID (− 3.41% to − 15.35% vs − 0.07% to − 4.32%) values than those using the same length plates without a proximal screw. Conclusions Based on the FEA results, buttress plates can improve construct mechanics, help to resist shear force and prevent varus collapse; under the modelling conditions, the use of a proximal screw on buttress plate may be a key technical feature in improving anti-shearing ability; additionally, this screw may be essential to reduce stress and prevent re-displacement of cannulated screws and fracture fragments.
- Subjects :
- musculoskeletal diseases
medicine.medical_specialty
Buttress
lcsh:Diseases of the musculoskeletal system
Buttress plate
Shear force
Bone Screws
Femoral Neck Fractures
03 medical and health sciences
Fracture Fixation, Internal
0302 clinical medicine
Rheumatology
medicine
Humans
Orthopedics and Sports Medicine
Biomechanics
Proximal screw
Orthodontics
030222 orthopedics
business.industry
Finite element analysis
Stiffness
030208 emergency & critical care medicine
Vertical femoral neck fracture
equipment and supplies
Finite element method
Biomechanical Phenomena
Orthopedic surgery
medicine.symptom
lcsh:RC925-935
business
Bone Plates
Research Article
Subjects
Details
- Language :
- English
- ISSN :
- 14712474
- Volume :
- 21
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- BMC Musculoskeletal Disorders
- Accession number :
- edsair.doi.dedup.....67e572f8d17133d70e243379c086adea