Back to Search
Start Over
A retrospective study of SPECT/CT scans using SUV measurement of the normal pelvis with Tc-99m methylene diphosphonate
- Source :
- International Journal of Radiology and Radiation Oncology. :003-008
- Publication Year :
- 2018
- Publisher :
- Peertechz Publications Private Limited, 2018.
-
Abstract
- Objective To perform quantitative measurement based on the standardized uptake value (SUV) of Tc-99m methylene diphosphonate (MDP) in the normal pelvis using a single-photon emission tomography (SPECT)/computed tomography (CT) scanner. Material and methods This retrospective study was performed on 31 patients with cancer undergoing bone SPECT/CT scans with 99mTc-MDP. SUVmax and SUVmean of the normal pelvis were calculated based on the body weight. SUVmax and SUVmean of the bilateral anterior superior iliac spine, posterior superior iliac spine, facies auricularis ossis ilii, ischial tuberosity, and sacrum were also calculated. Furthermore, the correlation of SUVmax and SUVmean of all parts of pelvis with weight, height, and CT was assessed. Results The data for 31 patients (20 women and 11 men; mean age 58.97±9.12 years; age range 37-87 years) were collected. SUVmax and SUVmean changed from 1.65±0.40 to 3.8±1.0 and from 1.15±0.25 to 2.07±0.58, respectively. The coefficient of variation of SUVmax and SUVmean ranged from 0.22 to 0.31. SUVmax and SUVmean had no statistically significant difference between men and women. SUVmax and SUVmean also showed no significant correlation with weight and height. However, part of SUVmax and SUVmean showed a significant correlation with CT. In addition, SUVmax and SUVmean of the bilateral ischial tuberosity showed a significant correlation with CT values. Conclusions Determination of the SUV value of the normal pelvis with 99m Tc-MDP SPECT/CT is feasible and highly reproducible. SUVs of the normal pelvis showed a relatively large variability. As a quantitative imaging biomarker, SUVs might require standardization with adequate reference data for the participant to minimize variability.
- Subjects :
- Male
Methylene diphosphonate
Coefficient of variation
Anterior superior iliac spine
Computed tomography
Standardized uptake value
Technetium Tc 99m Medronate
Pelvis
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Humans
Tc-99m Methylene Diphosphonate
Medicine
Radiology, Nuclear Medicine and imaging
Electrical and Electronic Engineering
Instrumentation
Aged
Pelvic Neoplasms
Retrospective Studies
Tomography, Emission-Computed, Single-Photon
Radiation
medicine.diagnostic_test
Phantoms, Imaging
business.industry
Body Weight
Retrospective cohort study
Middle Aged
Condensed Matter Physics
Sacrum
Ischial tuberosity
medicine.anatomical_structure
Normal pelvis
030220 oncology & carcinogenesis
Female
Tomography
Tomography, X-Ray Computed
Nuclear medicine
business
Posterior superior iliac spine
Subjects
Details
- ISSN :
- 26407566
- Database :
- OpenAIRE
- Journal :
- International Journal of Radiology and Radiation Oncology
- Accession number :
- edsair.doi.dedup.....6896eaa6cc1bf1318473b8245939323c