Back to Search Start Over

Can early phase cardiac [123I]mIBG images be used to diagnose Lewy body disease?

Authors :
Gemma Roberts
Joseph P.M. Kane
Jim Lloyd
Michael Firbank
Paul Christopher Donaghy
George S. Petrides
John-Paul Taylor
John O’Brien
Alan J. Thomas
Source :
Roberts, G, Kane, J PM, Lloyd, J, Firbank, M, Donaghy, P C, Petrides, G S, Taylor, J-P, O'Brien, J & Thomas, A J 2022, ' Can early phase cardiac [123I]mIBG images be used to diagnose Lewy body disease? ', Nuclear Medicine Communications . https://doi.org/10.1097/MNM.0000000000001581
Publication Year :
2022

Abstract

Purpose Some studies have suggested that cardiac [123I]metaiodobenzylguanidine images obtained 15–20 min after tracer administration are as accurate for dementia with Lewy bodies (DLB) diagnosis as standard images acquired after a delay of 3–4 h; some suggest delayed imaging is preferable. We compare early and delayed heart-to-mediastinum ratios (HMR) in a well-characterised research dataset and make recommendations for clinical practice.Methods Images were acquired using a Siemens gamma camera with medium energy collimators. Early images were obtained at 20 min and delayed at 4 h (± 30) min. In total 167 pairs of images were reviewed: 30 controls, 39 people with dementia and 98 with mild cognitive impairment. HMR normal cutoff values derived from control data were ≥2.10 for early imaging and ≥1.85 for delayed.Results HMR tended to drop between early and delayed for abnormal images, but increase for normal images. Histograms of early and delayed HMR showed a slightly better separation of results into two groups for delayed imaging. Accuracy results were slightly higher for delayed imaging than early imaging (73 vs. 77%), sensitivity 63 vs. 65% and specificity 82 vs. 88%. However, this was not statistically significant – in total only 8/167 (5%) of scans changed designation between early and delayed imaging.Conclusion We suggest that a delayed image could be acquired only if the early result is borderline. This removes the need for delayed imaging in about 70% of patients. Adopting this protocol in clinical practice would reduce the time most patients have to wait and could free up scanner time.

Details

Language :
English
Database :
OpenAIRE
Journal :
Roberts, G, Kane, J PM, Lloyd, J, Firbank, M, Donaghy, P C, Petrides, G S, Taylor, J-P, O'Brien, J & Thomas, A J 2022, ' Can early phase cardiac [123I]mIBG images be used to diagnose Lewy body disease? ', Nuclear Medicine Communications . https://doi.org/10.1097/MNM.0000000000001581
Accession number :
edsair.doi.dedup.....693c9e56bf149c85f1c79853fbcafb19
Full Text :
https://doi.org/10.1097/MNM.0000000000001581