Back to Search
Start Over
Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors
- Source :
- Journal of the American College of Cardiology. 53(12):1075-1081
- Publication Year :
- 2009
- Publisher :
- Elsevier BV, 2009.
-
Abstract
- ObjectivesThis study was designed to investigate the properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy system.BackgroundThe monitoring of CHF has relied mainly on right-side heart sensors.MethodsFifteen normal dogs underwent implantation of cardiac resynchronization therapy systems using standard leads. An additional left atrial (LA) pressure lead sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathoracic and intracardiac vectors, were measured through ring (r), coil (c), and device Can electrodes.ResultsCongestive heart failure developed in all animals after 2 to 4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr–Can, −17%; LVr–RVr, −15%; LVr–RAr, −11%; RVr–Can, −12%; RVc–Can, −7%; and RAr–Can, −5%. The LVr–Can vector reflected both the fastest and largest change in impedance in comparison with vectors employing only right-side heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure.ConclusionsImpedance, acquired by different lead electrodes, has variable responses to CHF. Impedance vectors employing an LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients.
- Subjects :
- Pacemaker, Artificial
medicine.medical_specialty
Heart disease
medicine.medical_treatment
Monitoring ambulatory
Cardiac resynchronization therapy
Monitoring, Ambulatory
Hemodynamics
cardiac resynchronization therapy
030204 cardiovascular system & hematology
hemodynamic monitoring
Article
03 medical and health sciences
Dogs
0302 clinical medicine
Internal medicine
Electric Impedance
Animals
Medicine
pulmonary edema
030212 general & internal medicine
Bioelectric Impedance
Heart Failure
business.industry
medicine.disease
Pulmonary edema
Electrodes, Implanted
Disease Models, Animal
Heart failure
Ambulatory
Ventricular Function, Right
Cardiology
business
Cardiology and Cardiovascular Medicine
Subjects
Details
- ISSN :
- 07351097
- Volume :
- 53
- Issue :
- 12
- Database :
- OpenAIRE
- Journal :
- Journal of the American College of Cardiology
- Accession number :
- edsair.doi.dedup.....69bc734dfdee281cfec19d997eed276f
- Full Text :
- https://doi.org/10.1016/j.jacc.2008.12.018