Back to Search Start Over

Reduction in Thyroid Nodule Biopsies and Improved Accuracy with American College of Radiology Thyroid Imaging Reporting and Data System

Authors :
William D. Middleton
Robert C. Vogler
Jill E. Langer
Daniel Scanga
Carl C. Reading
Nirvikar Dahiya
Jenny K. Hoang
Franklin N. Tessler
Sharlene A. Teefey
Barbara S. Hertzberg
Abraham J. Bronner
Justin R. Newman
Fernando J. Boschini
Alfredo E. Farjat
Nicole Abinanti
Source :
Radiology. 287(1)
Publication Year :
2018

Abstract

Purpose To compare the biopsy rate and diagnostic accuracy before and after applying the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) criteria for thyroid nodule evaluation. Materials and Methods In this retrospective study, eight radiologists with 3-32 years experience in thyroid ultrasonography (US) reviewed US features of 100 thyroid nodules that were cytologically proven, pathologically proven, or both in December 2016. The radiologists evaluated nodule features in five US categories and provided biopsy recommendations based on their own practice patterns without knowledge of ACR TI-RADS criteria. Another three expert radiologists served as the reference standard readers for the imaging findings. ACR TI-RADS criteria were retrospectively applied to the features assigned by the eight radiologists to produce biopsy recommendations. Comparison was made for biopsy rate, sensitivity, specificity, and accuracy. Results Fifteen of the 100 nodules (15%) were malignant. The mean number of nodules recommended for biopsy by the eight radiologists was 80 ± 16 (standard deviation) (range, 38-95 nodules) based on their own practice patterns and 57 ± 11 (range, 37-73 nodules) with retrospective application of ACR TI-RADS criteria. Without ACR TI-RADS criteria, readers had an overall sensitivity, specificity, and accuracy of 95% (95% confidence interval [CI]: 83%, 99%), 20% (95% CI: 16%, 25%), and 28% (95% CI: 21%, 37%), respectively. After applying ACR TI-RADS criteria, overall sensitivity, specificity, and accuracy were 92% (95% CI: 68%, 98%), 44% (95% CI: 33%, 56%), and 52% (95% CI: 40%, 63%), respectively. Although fewer malignancies were recommended for biopsy with ACR TI-RADS criteria, the majority met the criteria for follow-up US, with only three of 120 (2.5%) malignancy encounters requiring no follow-up or biopsy. Expert consensus recommended biopsy in 55 of 100 nodules with ACR TI-RADS criteria. Their sensitivity, specificity, and accuracy were 87% (95% CI: 48%, 98%), 51% (95% CI: 40%, 62%), and 56% (95% CI: 46%, 66%), respectively. Conclusion ACR TI-RADS criteria offer a meaningful reduction in the number of thyroid nodules recommended for biopsy and significantly improve the accuracy of recommendations for nodule management.

Details

ISSN :
15271315
Volume :
287
Issue :
1
Database :
OpenAIRE
Journal :
Radiology
Accession number :
edsair.doi.dedup.....6b1de816e93948a210c74accbe644762