Back to Search
Start Over
Comparison of Intracranial Aneurysms Treated by 2-D Versus 3-D Coils: A Matched-Pairs Analysis
- Source :
- Clinical Neuroradiology. 27:43-49
- Publication Year :
- 2015
- Publisher :
- Springer Science and Business Media LLC, 2015.
-
Abstract
- Knowledge on the influence of 2D and 3D coils to occlude intracranial aneurysms is poor. Therefore, aim of our analysis was to evaluate whether the use of 3-D versus 2-D coils alone may improve the efficacy of endovascular aneurysm treatment. We performed a matched pair analysis comparing aneurysms treated by 3-D coils as initial “framing” coils to aneurysms treated exclusively by 2-D coils. Number of coils, implanted coil length/volume, and associated packing density were calculated. Aneurysmal occlusion was assessed and monitored 6 months (DSA; magnetic resonance angiography (MRA)) and 18 months (MRA) after embolization. Periprocedural complications and retreatment rate of each group were analyzed. Our retrospective analysis revealed 50 pairs. Concerning the 3-D group, number of coils (353 in total, median 7; p = 0.002), implanted coil length (55.69 ± 48.4 cm), implanted coil length per volume (5.92 mm/mm3), and packing density (30 %; p = 0.017) was higher than in the 2-D group (259 in total, median 5 coils; 38.52 ± 43.13 cm; 4.54 mm/mm3; 23 %). Occlusion was not significantly different immediately after treatment but at 6 and 18 months follow-up in favor of 3-D coils. Retreatment was performed in 2 cases of the 3-D group and in 3 cases of the 2-D group and therefore in a similar range (p = 0.564). Initial use of 3-D coils revealed a higher packing density and a higher long-term occlusion. Therefore, we recommend initial use of 3-D coils.
- Subjects :
- Male
medicine.medical_specialty
Matched Pair Analysis
Matched-Pair Analysis
medicine.medical_treatment
Magnetic resonance angiography
030218 nuclear medicine & medical imaging
03 medical and health sciences
Postoperative Complications
0302 clinical medicine
Aneurysm treatment
Germany
Occlusion
Prevalence
medicine
Humans
Radiology, Nuclear Medicine and imaging
Longitudinal Studies
Embolization
Retrospective Studies
Neuroradiology
medicine.diagnostic_test
business.industry
Endovascular Procedures
Intracranial Aneurysm
Equipment Design
Middle Aged
Surgery
Equipment Failure Analysis
Treatment Outcome
Electromagnetic coil
Female
Neurology (clinical)
Nuclear medicine
business
030217 neurology & neurosurgery
After treatment
Subjects
Details
- ISSN :
- 18691447 and 18691439
- Volume :
- 27
- Database :
- OpenAIRE
- Journal :
- Clinical Neuroradiology
- Accession number :
- edsair.doi.dedup.....6d55d372e66fcd4d5d24b3fd6e8c9127
- Full Text :
- https://doi.org/10.1007/s00062-015-0408-9