Back to Search
Start Over
Digital health system for personalised COPD long-term management
- Source :
- BMC Medical Informatics and Decision Making, 2017, ' Digital health system for personalised COPD long-term management ', Bmc medical informatics and decision making, vol. 17, no. 1, pp. 19 . https://doi.org/10.1186/s12911-017-0414-8
- Publication Year :
- 2016
-
Abstract
- BACKGROUND: Recent telehealth studies have demonstrated minor impact on patients affected by long-term conditions. The use of technology does not guarantee the compliance required for sustained collection of high-quality symptom and physiological data. Remote monitoring alone is not sufficient for successful disease management. A patient-centred design approach is needed in order to allow the personalisation of interventions and encourage the completion of daily self-management tasks.METHODS: A digital health system was designed to support patients suffering from chronic obstructive pulmonary disease in self-managing their condition. The system includes a mobile application running on a consumer tablet personal computer and a secure backend server accessible to the health professionals in charge of patient management. The patient daily routine included the completion of an adaptive, electronic symptom diary on the tablet, and the measurement of oxygen saturation via a wireless pulse oximeter.RESULTS: The design of the system was based on a patient-centred design approach, informed by patient workshops. One hundred and ten patients in the intervention arm of a randomised controlled trial were subsequently given the tablet computer and pulse oximeter for a 12-month period. Patients were encouraged, but not mandated, to use the digital health system daily. The average used was 6.0 times a week by all those who participated in the full trial. Three months after enrolment, patients were able to complete their symptom diary and oxygen saturation measurement in less than 1 m 40s (96% of symptom diaries). Custom algorithms, based on the self-monitoring data collected during the first 50 days of use, were developed to personalise alert thresholds.CONCLUSIONS: Strategies and tools aimed at refining a digital health intervention require iterative use to enable convergence on an optimal, usable design. 'Continuous improvement' allowed feedback from users to have an immediate impact on the design of the system (e.g., collection of quality data), resulting in high compliance with self-monitoring over a prolonged period of time (12-month). Health professionals were prompted by prioritisation algorithms to review patient data, which led to their regular use of the remote monitoring website throughout the trial.TRIAL REGISTRATION: Trial registration: ISRCTN40367841 . Registered 17/10/2012.
- Subjects :
- 020205 medical informatics
Monitoring, Ambulatory
Automatic alerts
Health Informatics
02 engineering and technology
Telehealth
Pulmonary Disease, Chronic Obstructive/therapy
Health informatics
law.invention
03 medical and health sciences
Pulmonary Disease, Chronic Obstructive
0302 clinical medicine
Monitoring, Ambulatory/methods
Nursing
Randomized controlled trial
law
Adaptive thresholds
Telemedicine/methods
0202 electrical engineering, electronic engineering, information engineering
Self-management
Medicine
Humans
COPD
030212 general & internal medicine
Medical Informatics Applications
Oximetry
Self Care/methods
Disease management (health)
business.industry
Health Policy
medicine.disease
Digital health
Telemedicine
3. Good health
Computer Science Applications
Self Care
Data quality
Computers, Handheld
Personal computer
Medical emergency
business
Research Article
Subjects
Details
- ISSN :
- 14726947
- Volume :
- 17
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- BMC medical informatics and decision making
- Accession number :
- edsair.doi.dedup.....6f89fe269fd3cdd8d5036580ff40ae57
- Full Text :
- https://doi.org/10.1186/s12911-017-0414-8