Back to Search Start Over

A comparison of SanatMetal Sanat Swing and Zimmer NexGen® total knee implants: 10-year postoperative follow-up results

Authors :
Bence Abonyi
Tamás Gál
Iván Udvarhelyi
László Hangody
Károly Pap
Gábor Vásárhelyi
Source :
Joint Diseases and Related Surgery
Publication Year :
2021
Publisher :
Joint Diseases and Related Surgery, 2021.

Abstract

Objectives In this study, we present our 10-year postoperative follow-up results of Sanat Swing® and NexGen® total knee implants. Patients and methods A total of 189 patients (93 males, 96 females; mean age: 68 years; range, 48 to 86 years) who underwent total knee replacement between January 2008 and September 2010 were retrospectively analyzed. A total of 105 patients (Group A) were implanted a cemented Sanat Swing knee prosthesis and 84 patients (Group B) were implanted a cemented NexGen knee prosthesis. Operation time, range of motion (ROM), pain level, Knee Society Score (KSS), distance of painless walking, and the ability to climb stairs were evaluated between the groups. Results The mean follow-up was 10.8 (range, 9.8 to 12.3) years. No significant difference was observed in the survival of the prostheses, ROM, pain level, KSS, walking distance, and in the ability to climb stairs between the two groups at 10 years. With an experienced team, the operation time was about 4 to 5 min shorter in the Sanat Swing implantation group. In selected cases, Sanat Swing was superior to the NexGen system; however, there was no statistically significant difference. Complication rates were also low and comparable between both groups. Conclusion Based on the 10 years of follow-up evaluation, Sanat Swing total knee replacement system seems to yield comparable clinical results with the NexGen. Experiences with the operative technique and comparative evaluation, the Sanat Swing system is a safe and reliable alternative for total knee replacement, providing a user-friendly operative technique and shorter operation time.

Details

ISSN :
26874792 and 26874784
Volume :
32
Database :
OpenAIRE
Journal :
Joint Diseases and Related Surgery
Accession number :
edsair.doi.dedup.....7001bc0f8cc0508cfd77062bee73bab9
Full Text :
https://doi.org/10.5606/ehc.2021.76756