Back to Search Start Over

Development and Validation of Two Screening Assays for the Hepatitis C Virus NS3 Q80K Polymorphism Associated with Reduced Response to Combination Treatment Regimens Containing Simeprevir

Authors :
Chanson J. Brumme
Winnie Dong
Weiyan Dong
Jeffrey B. Joy
Art F. Y. Poon
P. R. Harrigan
Celia K. S. Chui
C. Beatty
H. Hew
Theresa Mo
Conan K. Woods
Source :
Journal of Clinical Microbiology. 53:2942-2950
Publication Year :
2015
Publisher :
American Society for Microbiology, 2015.

Abstract

Persons with hepatitis C virus (HCV) genotype 1a (GT1a) infections harboring a baseline Q80K polymorphism in nonstructural protein 3 (NS3) have a reduced virologic response to simeprevir in combination with pegylated interferon-alfa and ribavirin. We aimed to develop, validate, and freely disseminate an NS3 clinical sequencing assay to detect the Q80K polymorphism and potentially other HCV NS3 drug resistance mutations. HCV RNA was extracted from frozen plasma using a NucliSENS easyMAG automated nucleic acid extractor, amplified by nested reverse transcription-PCR, and sequenced using Sanger and/or next-generation (MiSeq) methods. Sanger chromatograms were analyzed using in-house software (RECall), and nucleotide mixtures were called automatically. MiSeq reads were iteratively mapped to the H77 reference genome, and consensus NS3 sequences were generated with nucleotides present at >20% called as mixtures. The accuracy, precision, and sensitivity for detecting the Q80K polymorphism were assessed in 70 samples previously sequenced by an external laboratory. A comparison of the sequences generated by the Sanger and MiSeq methods with those determined by an external lab revealed >98.5% nucleotide sequence concordance and zero discordant calls of the Q80K polymorphism. The results were both highly repeatable and reproducible (>99.7% nucleotide concordance and 100% Q80K concordance). The limits of detection (>2 and ∼5 log 10 IU/ml for the Sanger and MiSeq assays, respectively) are sufficiently low to allow genotyping in nearly all chronically infected treatment-naive persons. No systematic bias in the under- or overamplification of minority variants was observed. Coinfection with other viruses (e.g., HIV and hepatitis B virus [HBV]) did not affect the assay results. The two independent HCV NS3 sequencing assays with the automated analysis procedures described here are useful tools to screen for the Q80K polymorphism and other HCV protease inhibitor drug resistance mutations.

Details

ISSN :
1098660X and 00951137
Volume :
53
Database :
OpenAIRE
Journal :
Journal of Clinical Microbiology
Accession number :
edsair.doi.dedup.....708ec5e0c3b3dcd7d1af6d27410d5602
Full Text :
https://doi.org/10.1128/jcm.00650-15