Back to Search Start Over

Experimental quantification of the fluid dynamics in blood-processing devices through 4D-flow imaging: A pilot study on a real oxygenator/heat-exchanger module

Authors :
Emiliano Votta
Francesco Sturla
Alberto Redaelli
Riccardo Vismara
Sergii V. Siryk
Maria Chiara Palumbo
Filippo Consolo
Massimo Lombardi
Filippo Piatti
Andreas Greiser
Gianfranco Beniamino Fiore
Francesca Romana Pluchinotta
Piatti, Filippo
Palumbo, Maria Chiara
Consolo, Filippo
Pluchinotta, Francesca
Greiser, Andrea
Sturla, Francesco
Votta, Emiliano
Siryk, Sergii V.
Vismara, Riccardo
Fiore, Gianfranco Beniamino
Lombardi, Massimo
Redaelli, Alberto
Source :
Journal of Biomechanics. 68:14-23
Publication Year :
2018
Publisher :
Elsevier BV, 2018.

Abstract

The performance of blood-processing devices largely depends on the associated fluid dynamics, which hence represents a key aspect in their design and optimization. To this aim, two approaches are currently adopted: computational fluid-dynamics, which yields highly resolved three-dimensional data but relies on simplifying assumptions, and in vitro experiments, which typically involve the direct video-acquisition of the flow field and provide 2D data only. We propose a novel method that exploits space- and time-resolved magnetic resonance imaging (4D-flow) to quantify the complex 3D flow field in blood-processing devices and to overcome these limitations. We tested our method on a real device that integrates an oxygenator and a heat exchanger. A dedicated mock loop was implemented, and novel 4D-flow sequences with sub-millimetric spatial resolution and region-dependent velocity encodings were defined. Automated in house software was developed to quantify the complex 3D flow field within the different regions of the device: region-dependent flow rates, pressure drops, paths of the working fluid and wall shear stresses were computed. Our analysis highlighted the effects of fine geometrical features of the device on the local fluid-dynamics, which would be unlikely observed by current in vitro approaches. Also, the effects of non-idealities on the flow field distribution were captured, thanks to the absence of the simplifying assumptions that typically characterize numerical models. To the best of our knowledge, our approach is the first of its kind and could be extended to the analysis of a broad range of clinically relevant devices.

Details

ISSN :
00219290
Volume :
68
Database :
OpenAIRE
Journal :
Journal of Biomechanics
Accession number :
edsair.doi.dedup.....71e069a17342f8ac34cdee7466f5e5e2
Full Text :
https://doi.org/10.1016/j.jbiomech.2017.12.014