Back to Search
Start Over
Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
- Source :
- Journal of Korean Neurosurgical Society
- Publication Year :
- 2021
- Publisher :
- Korean Neurosurgical Society, 2021.
-
Abstract
- Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source.Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw.Results : The average radiation exposure/screw was 71.45±45.75 μSv/screw for group 1, 18.77±11.51 μSv/screw for group 2, 19.58±7.00 μSv/screw for group 3, and 4.26±2.89 μSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (
- Subjects :
- Percutaneous
medicine.medical_treatment
Radiation
Radiation dosage
Minimally invasive surgical procedures
fashion
medicine
Fluoroscopy
Pedicle screw
Reduction (orthopedic surgery)
Fixation (histology)
Dosimeter
Clinical Article
medicine.diagnostic_test
business.industry
General Neuroscience
Radiation exposure
Spine
fashion.garment
Lead apron
Surgery
Neurology (clinical)
business
Nuclear medicine
Subjects
Details
- Language :
- English
- ISSN :
- 15987876 and 20053711
- Volume :
- 64
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Journal of Korean Neurosurgical Society
- Accession number :
- edsair.doi.dedup.....72ededc3ed2af8515072458fbf2ee7a9