Back to Search
Start Over
Hepatometria ultra-sonográfica em crianças: proposta de novo método
- Source :
- Radiologia Brasileira v.36 n.2 2003, Radiologia Brasileira, Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR), instacron:CBR, Radiologia Brasileira, Vol 36, Iss 2, Pp 63-70 (2003), Radiologia Brasileira, Volume: 36, Issue: 2, Pages: 63-70, Published: MAR 2003
- Publication Year :
- 2003
- Publisher :
- Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, 2003.
-
Abstract
- OBJETIVO: Padronizar método ultra-sonográfico de biometria hepática em crianças, visando estabelecer maior precisão nos planos de corte e minimizar o fator operador-dependência; testar a reprodutibilidade intra-observador. CASUÍSTICA E MÉTODO: A hepatometria ultra-sonográfica foi realizada em 32 crianças, entre 0 e 6 anos de idade, sem doença hepática ou das vias biliares. Todas as crianças foram examinadas por um mesmo observador, em duas ocasiões diferentes (exames 1 e 2). Os planos seccionais foram estabelecidos inter-relacionando linhas de orientação externas a reparos anatômicos intra-abdominais, extra e intra-hepáticos. Para análise comparativa das medidas dos exames 1 e 2 foi utilizado o teste t pareado. O coeficiente de Pearson foi empregado para análise de correlação: a) dos parâmetros entre si; b) entre a idade das crianças e a diferença das medidas dos exames 1 e 2. RESULTADOS: À análise estatística não houve: a) diferença significante no estudo da variabilidade intra-observador; b) correlação significante entre a diferença das medidas e as idades dos pacientes. Verificamos que os parâmetros estão, no geral, direta e altamente correlacionados entre si (r > 0,60). CONCLUSÃO: O método é reprodutível por um mesmo observador. As medidas dos diâmetros crânio-caudal na linha médio-esternal e crânio-caudal posterior na linha hemiclavicular, usando referenciais anatômicos intra-hepáticos, mostraram-se precisas e mais práticas que as demais. OBJECTIVE: The objectives of this study are: (1) to standardize the sonographic biometry method to determine the size of the liver in children in order to obtain a greater precision of the section planes and to minimize operator-dependant error; (2) to test intra-observer reproducibility. CASUISTIC AND METHOD: Sonographic measurements of the liver were performed by a single examiner in 32 children (aged 0 to 6 years) with no liver or biliary system disease. The measurements were done in two different occasions (exams 1 and 2) to determine reproducibility. The section planes were based on external orientation lines related to intra-abdominal anatomic references, both extra and intra-hepatic. The values obtained in exams 1 and 2 were compared using a Student's paired t-test. The Pearson's coefficient was employed to determine the correlation among parameters as well as the correlation between the children's age and the difference in the values of exams 1 and 2. RESULTS: The statistical analysis revealed no significant intra-observer variability and no significant correlation between measurements' difference and children's age. In general, parameters were directly and highly correlated (r > 0.60). CONCLUSION: We concluded that the method is reproducible when performed by a same examiner. The measurements of the cranio-caudal diameter at the midsternal line and the posterior cranio-caudal diameter at the midclavicular line, based on intra-hepatic anatomic references, were precise and easier to perform than other routine measurements.
- Subjects :
- lcsh:Medical physics. Medical radiology. Nuclear medicine
medicine.medical_specialty
Biometry
Midsternal line
Fígado/dimensões
Crianças
lcsh:R895-920
R895-920
Correlation
Medical physics. Medical radiology. Nuclear medicine
Fígado
Ultra-som
Ultrasound
medicine
Radiology, Nuclear Medicine and imaging
Statistical analysis
Children
Mathematics
Biometria
Reproducibility
business.industry
Surgery
MIdclavicular line
Liver size
Nuclear medicine
business
Subjects
Details
- Language :
- Portuguese
- Database :
- OpenAIRE
- Journal :
- Radiologia Brasileira v.36 n.2 2003, Radiologia Brasileira, Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR), instacron:CBR, Radiologia Brasileira, Vol 36, Iss 2, Pp 63-70 (2003), Radiologia Brasileira, Volume: 36, Issue: 2, Pages: 63-70, Published: MAR 2003
- Accession number :
- edsair.doi.dedup.....75655f0cc1645d2db40881cc074f3053