Back to Search Start Over

Evaluation of Severe Acute Respiratory Syndrome Coronavirus 2 Nucleocapsid Antigen in the Blood as a Diagnostic Test for Infection and Infectious Viral Shedding

Authors :
Sujata, Mathur
Michelle C, Davidson
Khamal, Anglin
Scott, Lu
Sarah A, Goldberg
Miguel, Garcia-Knight
Michel, Tassetto
Amethyst, Zhang
Mariela, Romero
Jesus, Pineda-Ramirez
Ruth, Diaz-Sanchez
Paulina, Rugart
Jessica Y, Chen
Kevin, Donohue
Joshua R, Shak
Ahmed, Chenna
John W, Winslow
Christos J, Petropoulos
Brandon C, Yee
Jeremy, Lambert
David V, Glidden
George W, Rutherford
Steven G, Deeks
Michael J, Peluso
Raul, Andino
Jeffrey N, Martin
J Daniel, Kelly
Source :
Open forum infectious diseases, vol 9, iss 11
Publication Year :
2022
Publisher :
eScholarship, University of California, 2022.

Abstract

Background SARS-CoV-2 nucleocapsid antigen can be detected in plasma, but little is known about its performance as a diagnostic test for acute SARS-CoV-2 infection or infectious viral shedding among nonhospitalized individuals. Methods We used data generated from anterior nasal and blood samples collected in a longitudinal household cohort of SARS-CoV-2 cases and contacts. Participants were classified as true positives if polymerase chain reaction (PCR) positive for SARS-CoV-2 and as true negatives if PCR negative and seronegative. Infectious viral shedding was determined by the cytopathic effect from viral culture. Stratified by 7 days after symptom onset, we constructed receiver operating characteristic (ROC) curves to describe optimized accuracy (Youden index), optimized sensitivity, and specificity. Results Of 80 participants, 58 (73%) were true positives while 22 (27%) were true negatives. Using the manufacturer's cutoff of 1.25 pg/mL for evaluating infection, sensitivity was higher from 0 to 7 days (77.6% [95% confidence interval {CI}, 64%–88.2%]) than from 8 to 14 days (43.2% [95% CI, 31.1%–54.5%]) after symptom onset; specificity was unchanged at 100% (95% CI, 88.1%–100%). This test had higher sensitivity (100% [95% CI, 88.4%–100%]) and lower specificity (65% [95% CI, 40.8%–84.6%]) for infectious viral shedding as compared with infection, particularly within the first week of symptom onset. Although the presence of N-antigen correlated with infectious viral shedding (r = 0.63; P < .01), sensitivity still declined over time. Additional cutoffs from ROC curves were identified to optimize sensitivity and specificity. Conclusions We found that this SARS-CoV-2 N-antigen test was highly sensitive for detecting early but not late infectious viral shedding, making it a viable screening test for community-dwelling individuals to inform isolation practices.

Details

Database :
OpenAIRE
Journal :
Open forum infectious diseases, vol 9, iss 11
Accession number :
edsair.doi.dedup.....78539e1f3f5fc799990c96a8aff66eca