The modified protocol of transesophageal atrial pacing in stress echocardiography as an alternative way to increase the information value of the method for detection of ischemic wall motion abnormalities
- Source :
- Kardiologiia. 61:71-76
- Publication Year :
- 2021
- Publisher :
- APO Society of Specialists in Heart Failure, 2021.
-
Abstract
- Aim To develop a new, modified protocol for transesophageal atrial electric stimulation (TEAES), which would significantly enhance the diagnostic value of stress echocardiography and reduce the duration of the test in patients with ischemic heart disease (IHD).Material and methods This study included 101 patients (80 men and 21 women aged 55±9 years) with suspected or documented diagnosis of IHD who were divided into two homogenous groups. Group 1 (51 patients) underwent stress echocardiography (stress-EchoCG) according to a standard protocol (SP) for TEAES and group 2 (50 patients), underwent stress-EchoCG according to a modified protocol (MP). In addition to stress-EchoCG with TEAES, selective coronary angiography was performed for all patients. The development of the new method for evaluating occult coronary insufficiency was based on comparison of SP and MP for TEAES with stress-EchoCG with data of coronary angiography.Results In both groups, significant differences in values of systolic and diastolic blood pressure were absent. However, the values of achieved heart rate were significantly different: 141±11 (TEAES SP) and 155±10 (TEAES MP) bpm (p=0.01). There was also a difference in the duration of the TEAES protocols: 15±3 and 5±2 min, respectively (p=0.006). The use of the modified TEAES protocol for detecting transient disorders of left ventricular myocardial local contractility increased the sensitivity, specificity and accuracy of the test from 76 %, 87 %, and 80 % to 83 %, 92 %, and 86 %, respectively. The most significant differences were found in the area supplied by the circumflex artery: the SP and MP sensitivities were 63 % and 75 %, respectively (pConclusion Evaluation of occult coronary insufficiency by stress-EchoCG with the TEAES MP as compared to the TEAES SP provides a gentler procedure regimen for the patient due to a shorter duration of the test and at the same time improves the diagnostic significance of this method in IHD patients.
- Subjects :
- Male
medicine.medical_specialty
Myocardial Ischemia
Coronary Disease
030204 cardiovascular system & hematology
Coronary Angiography
Sensitivity and Specificity
Contractility
03 medical and health sciences
0302 clinical medicine
Internal medicine
Heart rate
Stress Echocardiography
Humans
Medicine
Heart Atria
Circumflex
Atrial pacing
business.industry
030229 sport sciences
Middle Aged
Regimen
Blood pressure
medicine.anatomical_structure
Exercise Test
Cardiology
Female
Cardiology and Cardiovascular Medicine
business
Echocardiography, Stress
Artery
Subjects
Details
- ISSN :
- 24125660 and 00229040
- Volume :
- 61
- Database :
- OpenAIRE
- Journal :
- Kardiologiia
- Accession number :
- edsair.doi.dedup.....79028c69645c2cdf7467964a745cc987
- Full Text :
- https://doi.org/10.18087/cardio.2021.3.n1248