Comparison of Fracture Strengths among different Commonly Placed Anterior Esthetic Restorations for Primary Dentition: An in vitro study

Authors :
Brent Lin
Michael Hong
Amit Khatri
Source :
Journal of Clinical Pediatric Dentistry. 45:171-176
Publication Year :
2021
Publisher :
MRE Press, 2021.

Abstract

The purpose of this study was to determine and compare the shear force (N) required to fracture or dislodge an all-ceramic zirconia-based crown using different luting cement with those of polycarbonate crown and strip crown for the primary anterior teeth in vitro. Study design: Four groups of esthetic restoration for primary anterior teeth were tested for fracture strength: 1) Fifteen all-ceramic zirconia-based crowns cemented with glass ionomer cement, 2) Fifteen all-ceramic zirconia-based crowns bonded with a self-adhesive resin cement, 3) Fifteen polycarbonate crowns cemented with a polymer reinforced zinc-oxide eugenol and 4) Fifteen resin strip crowns. All restorations were placed and cemented on reproductions of dies in an independent laboratory at Delhi, India. All samples underwent loading until fracture or dislodgement with the Universal Testing Machine. The force in Newton (N) required to produce failure was recorded for each sample and the type of failures was also noted and characterized. One-way analysis of variance (ANOVA) test and the Tukey and Scheffe’s post hoc comparisons were used for statistical analyses. Results: In this invitro study, results were measured in Newtons (N). Group 1 (410.9±79.5 N) and Group 2 (420.5±57.8 N) had higher fracture strength than Group 3 (330.3±85.6 N) and Group 4 (268.4±28.2 N). These differences were statistically significant at P≤.05 among the sample groups. No significant difference was found between groups 1 and 2 (P = 0.984) nor between groups 3 and 4 (P =0.104). Among type of failures, majority of restoration fractures for zirconia-based crowns and resin strip crowns were due to cohesive failures and polycarbonate crowns had predominantly mixed failures. Conclusions: Under the limitations of this in vitro study, it could be concluded that all-ceramic zirconia-based crowns attained the highest fracture strength among all restorative samples tested regardless of the type of luting agent employed (P

Details

ISSN :
10534628
Volume :
45
Database :
OpenAIRE
Journal :
Journal of Clinical Pediatric Dentistry
Accession number :
edsair.doi.dedup.....79a6d725317d93e2d5d5970d05fd4227
Full Text :
https://doi.org/10.17796/1053-4625-45.3.5