Back to Search
Start Over
Feasibility of CAIPIRINHA-Dixon-TWIST-VIBE for dynamic contrast-enhanced MRI of the prostate
- Source :
- European Journal of Radiology. 84:2110-2116
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- To evaluate the feasibility of a CAIPIRINHA-Dixon-TWIST (CDT)-VIBE sequence for improving image quality and temporal resolution in dynamic contrast-enhanced MRI (DCE-MRI) of the prostate.44 male patients (age 63.9 ± 8.9 years) with clinically suspected prostate cancer underwent DCE-MRI at a 3T MRI scanner (Magnetom Skyra, Siemens Healthcare, Erlangen, Germany) using a CDT-VIBE sequence (spatial resolution=3×1.2×1.2mm(3), temporal resolution=5s, total scan duration=4:10 min) with body-weight-adapted administration of contrast agent (Gadobutrol, Bayer Healthcare, Berlin, Germany). To investigate effects on image quality, the same sequence was acquired three times per patient during the late phase: 1. with the same protocol as in the arterial phase (VS5), 2. without view-sharing (no view-sharing, NVS) using a 2-fold CAIPIRINHA acceleration R=2 (temporal resolution=15s, NVS15) and 3. NVS using a 6-fold CAIPIRINHA acceleration R=6 (temporal resolution=5s, NVS5). SNR and CNR were evaluated with the subtraction method. Image quality of the three sequences (VS5, NVS15, NVS5) was subjectively assessed by 2 blinded radiologists using a 5-point Likert scale (5 being excellent). Perfusion profiles of visually normal prostate and of malignant lesions as characterized by Wash-In, Wash-Out, time-to-peak (TTP) and initial area under the curve (iAUC) from the original datasets (temporal resolution=5s) and from datasets with a downsampled temporal resolution (15s) were compared.In 20 of 44 included patients, potentially malignant lesions were identified in which 16 had histologically confirmed prostate cancer. SNR was highest for VS5 and NVS15, and lowest for NVS5 (p.001). Concordantly, subjective image quality was comparable for VS5 and NVS15 (sum score 23.20 ± 1.03 vs 23.53 ± 1.34) and significantly lower for NVS5 (sum score 9.83 ± 2.32; p.001). Perfusion parameters of macroscopically normal prostate tissue and suspect lesions differed significantly between original datasets and datasets with simulated lower temporal resolution, with the latter showing higher Wash-In (p=.002), lower Wash-Out (p=.003), higher Time-to-Peak (p.001) and lower iAUC (p.001).CDT-VIBE can be readily exploited for DCE-MRI of the prostate preserving the diagnostic image quality while providing high temporal resolution for quantitative diagnostic assessment of enhancement curves in malignant lesions.
- Subjects :
- Male
medicine.medical_specialty
Image quality
Dynamic imaging
Contrast Media
Gadobutrol
Region of interest
Image Interpretation, Computer-Assisted
Organometallic Compounds
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Aged
Observer Variation
Analysis of Variance
medicine.diagnostic_test
business.industry
Prostate
Prostatic Neoplasms
Reproducibility of Results
Magnetic resonance imaging
General Medicine
Middle Aged
Image Enhancement
Magnetic Resonance Imaging
PI-RADS
Temporal resolution
Dynamic contrast-enhanced MRI
Feasibility Studies
Radiology
business
Nuclear medicine
medicine.drug
Subjects
Details
- ISSN :
- 0720048X
- Volume :
- 84
- Database :
- OpenAIRE
- Journal :
- European Journal of Radiology
- Accession number :
- edsair.doi.dedup.....79f27509f3addce3b5af1e35cad55e6a