Multicenter Repeatability Study of a Novel Quantitative Diffusion Kurtosis Imaging Phantom
- Source :
- Tomography; Volume 5; Issue 1; Pages: 36-43, Tomography, Volume 5, Issue 1, Pages 36-43
- Publication Year :
- 2019
- Publisher :
- MDPI AG, 2019.
-
Abstract
- Quantitative kurtosis phantoms are sought by multicenter clinical trials to establish accuracy and precision of quantitative imaging biomarkers on the basis of diffusion kurtosis imaging (DKI) parameters. We designed and evaluated precision, reproducibility, and long-term stability of a novel isotropic (i) DKI phantom fabricated using four families of chemicals based on vesicular and lamellar mesophases of liquid crystal materials. The constructed iDKI phantoms included negative control monoexponential diffusion materials to independently characterize noise and model-induced bias in quantitative kurtosis parameters. Ten test–retest DKI studies were performed on four scanners at three imaging centers over a six-month period. The tested prototype phantoms exhibited physiologically relevant apparent diffusion, Dapp, and kurtosis, Kapp, parameters ranging between 0.4 and 1.1 (×10−3 mm2/s) and 0.8 and 1.7 (unitless), respectively. Measured kurtosis phantom Kapp exceeded maximum fit model bias (0.1) detected for negative control (zero kurtosis) materials. The material-specific parameter precision [95% CI for Dapp: 0.013–0.022(×10−3 mm2/s) and for Kapp: 0.009–0.076] derived from the test–retest analysis was sufficient to characterize thermal and temporal stability of the prototype DKI phantom through correlation analysis of inter-scan variability. The present study confirms a promising chemical design for stable quantitative DKI phantom based on vesicular mesophase of liquid crystal materials. Improvements to phantom preparation and temperature monitoring procedures have potential to enhance precision and reproducibility for future multicenter iDKI phantom studies.
- Subjects :
- diffusion kurtosis
Accuracy and precision
Materials science
micro-scale lamellar vesicles
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Image Interpretation, Computer-Assisted
Humans
Radiology, Nuclear Medicine and imaging
repeatability
temporal stability
Diffusion Kurtosis Imaging
Research Articles
Reproducibility
Phantoms, Imaging
Temperature
Reproducibility of Results
Equipment Design
Repeatability
Liquid Crystals
tunable parameters
Diffusion Magnetic Resonance Imaging
030220 oncology & carcinogenesis
Kurtosis
Phantom studies
Chemical design
Biomedical engineering
Subjects
Details
- ISSN :
- 2379139X
- Volume :
- 5
- Database :
- OpenAIRE
- Journal :
- Tomography
- Accession number :
- edsair.doi.dedup.....7a37ca71476e406e31b8460fd9644387