Back to Search
Start Over
Intrastromal corneal ring for low myopia: a comparative study with LASIK
- Source :
- Arquivos Brasileiros de Oftalmologia, Vol 67, Iss 1, Pp 13-22 (2004), Arquivos Brasileiros de Oftalmologia, Volume: 67, Issue: 1, Pages: 13-22, Published: FEB 2004, Arquivos Brasileiros de Oftalmologia v.67 n.1 2004, Arquivos brasileiros de oftalmologia, Conselho Brasileiro de Oftalmologia (CBO), instacron:CBO
- Publication Year :
- 2004
- Publisher :
- Conselho Brasileiro de Oftalmologia, 2004.
-
Abstract
- OBJETIVO: Avaliar prospectivamente a eficácia e segurança dos segmentos de anéis corneanos intra-estromais (ICRS) para a correção de baixa miopia e comparar os resultados obtidos com a técnica de laser in situ keratomileusis (LASIK). MÉTODOS: Estudo prospectivo, bilateral e não randomizado. Quatorze pacientes com equivalente esférico entre -1,00 e -4,50 D foram submetidos ao implante de ICRS em um olho e à técnica de LASIK no olho contralateral. As avaliações pós-operatórias foram realizadas com um e sete dias, um, três, seis, 12 e 24 meses. RESULTADOS: Ao último exame, 64,29% dos olhos (9/14) do grupo ICRS e 85,71% (12/14) após o LASIK estavam entre ± 0,50 D da correção desejada (p=0,385). Acuidade visual sem correção >20/20 foi obtida em quatro dos 14 olhos (28,57%) do grupo ICRS, e em 12 dos 14 olhos (85,71%) do grupo LASIK (p=0,002¹). Durante o seguimento, não foram observadas variações refracionais superiores a 1,00 D, entre dois exames consecutivos, em ambos os grupos, ou perda significante da melhor acuidade visual corrigida. Maior indução de astigmatismo foi encontrada nos olhos implantados com ICRS. Ao exame de 24 meses, o grupo ICRS apresentou valores inferiores no exame de sensibilidade ao contraste, especialmente nas freqüências espaciais mais altas (p=0,032¹ em 18 cpd). Foram relatadas mais queixas subjetivas no período pós-operatório precoce de ICRS em relação ao LASIK. CONCLUSÕES: Os ICRS foram considerados eficazes na correção de baixa miopia, porém sua segurança foi limitada pela indução de astigmatismo no pós-operatório, e seus resultados foram inferiores aos do grupo controle. PURPOSE: To evaluate the efficacy and safety of intrastromal corneal ring segments (ICRS) for the correction of low myopia, and to compare the obtained results with a control group submitted to laser in situ keratomileusis (LASIK). METHODS: Prospective, nonrandomized and bilateral study. Fourteen patients with preoperative spherical equivalent ranging from -1.00 to -4.50 D received ICRS in one eye and LASIK in the other. Postoperative evaluations were performed at day one and seven and months 1, 3, 6, 12 and 24. RESULTS: At the last follow-up, 64.29% of ICRS eyes (9/14) and 85.71% of LASIK eyes (12/14) were within ± 0.50 D of the predicted refractive outcome (p=0.385). Uncorrected visual acuity of 20/20 or better was observed in four of 14 ICRS eyes (28.57%), and in 12 of 14 LASIK eyes (85.71%) (p=0.002²). No variances of more than 1.00 D in the manifest spherical equivalent refraction between two consecutive examinations or significant loss of best spectacle-corrected visual acuity were observed in both groups. Surgically induced astigmatism was greater in ICRS eyes than in LASIK eyes. At 24 months, the ICRS eyes scored lower in contrast sensitivity testing, especially at higher spatial frequencies (p=0.032² at 18 cpd). The patients reported more subjective complaints in the early postoperative period for the ICRS eyes. CONCLUSIONS: ICRS were considered effective for the correction of low myopia, but their safety was limited by the observed surgically induced astigmatism, and their results were inferior compared to the control group.
- Subjects :
- medicine.medical_specialty
Visual acuity
genetic structures
animal diseases
medicine.medical_treatment
Miopia
Keratomileusis
Spherical equivalent
Uncorrected visual acuity
Prosthesis implantation
Cornea
lcsh:Ophthalmology
Ophthalmology
medicine
Myopia
Ceratomileuse assistida por excimer laser in situ
business.industry
Miopia/classificação
LASIK
General Medicine
RE1-994
Laser in situ keratomileusis
eye diseases
Surgery
Córnea
lcsh:RE1-994
Sensitivity testing
Córnea/cirurgia
Miopia/cirurgia
Surgically induced astigmatism
Implante de prótese
sense organs
Corneal ring
medicine.symptom
business
Subjects
Details
- Language :
- English
- ISSN :
- 16782925
- Volume :
- 67
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Arquivos Brasileiros de Oftalmologia
- Accession number :
- edsair.doi.dedup.....7bcada6b8bd100156b4f0b7a0a97592b