Back to Search Start Over

Quality control of regional wall motion analysis in stress Echo 2020

Authors :
Ivan Stankovic
Bruno Villari
Jorge Lowenstein
Antonello D'Andrea
Angela Zagatina
Marco Fabio Costantino
Sergio Severino
Fausto Rigo
Maria Chiara Scali
Ayana Arystan
Marco Paterni
Clara Carpeggiani
Iana Simova
Jelena Celutkiene
Maurizio Galderisi
Albert Varga
Rodolfo Citro
Marco Antonio Rodrigues Torres
Lauro Cortigiani
Nicola Gaibazzi
Paolo Colonna
Jarosław D. Kasprzak
Eugenio Picano
Ana Djordjevic-Dikic
Giovanni Di Salvo
Daniel Quesada Chaves
Ines Monte
Quirino Ciampi
Pablo Merlo
Fabio Mori
Clarissa Borguezan Daros
Federica Re
Paolo Trambaiolo
Julio E. Pérez
Claudio Dodi
Michele De Nes
Milica Dekleva
Aleksander Neskovic
Laura Massa
Miguel Amor
José Luis de Castro e Silva Pretto
Ciampi, Quirino
Picano, Eugenio
Paterni, Marco
Daros, Clarissa Borguezan
Simova, Iana
Josã© Luis, De Castro E. Silva Pretto
Scali, Maria Chiara
Gaibazzi, Nicola
Severino, Sergio
Djordjevic dikic, Ana
Kasprzak, Jaroslaw D.
Zagatina, Angela
Varga, Albert
Lowenstein, Jorge
Merlo, Pablo Martin
Amor, Miguel
Celutkiene, Jelena
Perez, Julio E.
DI SALVO, Giovanni
Galderisi, Maurizio
Mori, Fabio
Costantino, Marco Fabio
Massa, Laura
Dekleva, Milica
Chaves, Daniel Quesada
Trambaiolo, Paolo
Citro, Rodolfo
Colonna, Paolo
Rigo, Fausto
Torres, Marco A. R.
Monte, Ine
Stankovic, Ivan
Neskovic, Aleksander
Cortigiani, Lauro
Re, Federica
Dodi, Claudio
D'Andrea, Antonello
Villari, Bruno
Arystan, Ayana
De Nes, Michele
Carpeggiani, Clara
de Castro e Silva Pretto, José Lui
Djordjevic-Dikic, Ana
Di Salvo, Giovanni
Source :
International journal of cardiology. 249
Publication Year :
2017

Abstract

Background: The trial "Stress Echo (SE) 2020" evaluates novel applications of SE beyond coronary artery disease. The aim of the study was control quality and harmonize reading criteria.Methods: One reader from 78 centers of the SE 2020 network asked for credentials to read a set of 20 SE videoclips selected by the core lab. All aspiring centers met the pre-requisite of high-volume and the years of experience in SE ranged from 5 to 31 years (mean value 18 years). The diagnostic gold standard was a reading by the core lab. The a priori determined pass threshold was 18/20 (>= 90%).Results: Of the initial 78 who started, 57 completed the first attempt: individual readers' score on first attempt ranged from 07/20 to 20/20 (accuracy from 35% to 100%, mean 78.7 +/- 13%) and 44 readers passed it. There was a very poor correlation between years of experience and the reader's score on first attempt (r = -0.161, p = 0.231). Of the 13 readers who failed the first attempt, 12 took it again after the web-based session and their accuracy improved (74% vs. 96%, p < 0.001). The kappa inter-observer agreement before and after web-based training was 0.59 on first attempt and rose to 0.91 on the last attempt.Conclusions: In SE reading, the volume of activity or years of experience is not synonymous with diagnostic quality. Qualitative analysis and operator-dependence can become a limiting weakness in clinical practice, in the absence of strict pathways of learning, credentialing and audit. (C) 2017 Elsevier B.V. All rights reserved.

Details

ISSN :
18741754
Volume :
249
Database :
OpenAIRE
Journal :
International journal of cardiology
Accession number :
edsair.doi.dedup.....7c10190074e57941411c8eb17a3a43c5