Colourimetric characterisation of disposable optical sensors from spectroradiometric measurements

Authors :
Manuel Melgosa
Rafael Huertas
Alejandro Lapresta-Fernández
Luis Fermín Capitán-Vallvey
Source :
Analytical and Bioanalytical Chemistry. 393:1361-1366
Publication Year :
2008
Publisher :
Springer Science and Business Media LLC, 2008.

Abstract

Spectroradiometric measurements of reflectance and CIELAB hue-angle, were tested for K(I) determination using disposable optical sensors based on ion exchange mechanism. The linearisation of the sigmoidal response function, using a logistic regression, increases the linear range noticeably to 7.65 x 10(-8)-1.5 M and 1.22 x 10(-7)-1.5 M for CIELAB hue-angle and reflectance, respectively. The trueness of both procedures was demonstrated comparing it with results obtained by a DAD spectrophotometer used as a reference measurement procedure. The usefulness of the procedure was checked by analysing K(I) in different types of waters and beverages. Additionally, we studied the possible visual discrimination for the whole potassium range tested, obtaining the possibility of discriminating twelve groups of concentrations.

Details

ISSN :
16182650 and 16182642
Volume :
393
Database :
OpenAIRE
Journal :
Analytical and Bioanalytical Chemistry
Accession number :
edsair.doi.dedup.....7e3afba03c10fb30d46b97062c176fbf
Full Text :
https://doi.org/10.1007/s00216-008-2552-4