Back to Search
Start Over
Evaluation of a six‐dye multiplex composed of 27 markers for forensic analysis and databasing
- Source :
- Molecular Genetics & Genomic Medicine, Vol 8, Iss 9, Pp n/a-n/a (2020), Molecular Genetics & Genomic Medicine
- Publication Year :
- 2020
- Publisher :
- Wiley, 2020.
-
Abstract
- Background Short tandem repeat (STR) markers play a significant role in genetic applications and have proved to be effective for the personal identification in forensic medicine. In this study, a six‐dye multiplex composed of 23 autosomal STR loci (TH01, D3S1358, Penta D, D6S1043, D21S11, TPOX, D1S1656, D12S391, Penta E, D10S1248, D22S1045, D19S433, D8S1179, D2S1338, D2S441, D18S51, vWA, FGA, D16S539, CSF1PO, D13S317, D5S818, D7S820), one Y chromosome STR (DYS391), two internal quality control markers (Quality Sensor QS1 and QS2), and Amelogenin was evaluated. Methods Evaluation studies, including PCR‐based studies, sensitivity studies, species specificity studies, stability studies, DNA mixture studies, concordance studies, and precision evaluations were performed according to the guidelines of “Validation Guidelines for Forensic DNA Analysis Methods (2016)” by the Scientific Working Group on DNA Analysis Methods (SWGDAM). In addition, the forensic characteristics of 357 unrelated male samples from Han and Hui populations in China were investigated using 27 markers. Results Full STR profiles were obtained from different reaction volumes (5 ~ 25 μl), cycle numbers (28 ~ 34 cycles) and annealing temperatures (58 ~ 62°C). All STR profiles were obtained at humic acid concentration of up to 200 ng/μl and hematin concentration of up to 500 μM. No peaks were observed in most common animal samples except two innovative internal PCR controls (Quality Sensor QS1 and QS2). The six‐dye multiplex showed a notably high value for the combined probability of exclusion (CPE), exhibiting values of with 0.99999999977688 in the Han population and 0.999999999583875 in the Hui population. The values of combined probability of discrimination (CPD) were 0.999999999999999999999999999997453 in the Han population and 0. 999999999999999999999999999994398 in the Hui population. In addition, concordance studies showed that there was no difference with the AGCU Express Marker 22 Kit. Conclusion The results indicated that the Investigator® 26plex QS Kit is a robust, reliable, and suitable tool for forensic analysis and databasing.<br />A 6‐dye multiplex composed of 27 markers were evaluated, according to SWGDAM guidelines.High power of discrimination and cumlative probability of paternity exculsion value in two Chinese population.The 6‐dye multiplex is robust, reliable and suitable tool for forensic analysis and data‐basing.
- Subjects :
- 0301 basic medicine
Forensic Genetics
Genetic Markers
Male
lcsh:QH426-470
Concordance
forensic science
Population
030105 genetics & heredity
Biology
Y chromosome
Sensitivity and Specificity
03 medical and health sciences
Databases, Genetic
short tandem repeat (STR)
Genetics
concordance study
Chromosomes, Human
Humans
Multiplex
education
Molecular Biology
Genetics (clinical)
Fluorescent Dyes
education.field_of_study
Original Articles
Reference Standards
sensitivity
Molecular biology
Internal quality
Forensic science
lcsh:Genetics
030104 developmental biology
Microsatellite
mixture study
Female
Original Article
Amelogenin
Multiplex Polymerase Chain Reaction
Microsatellite Repeats
Subjects
Details
- Language :
- English
- ISSN :
- 23249269
- Volume :
- 8
- Issue :
- 9
- Database :
- OpenAIRE
- Journal :
- Molecular Genetics & Genomic Medicine
- Accession number :
- edsair.doi.dedup.....7f439cd13f72c13093dfc645a1436ed6