Back to Search Start Over

Custom CAD/CAM implants for complex craniofacial reconstruction in children: Our experience based on 136 casesāœ°

Authors :
Christopher R. Forrest
David Y. Khechoyan
John H. Phillips
Phuong D. Nguyen
Source :
Journal of Plastic, Reconstructive & Aesthetic Surgery. 71:1609-1617
Publication Year :
2018
Publisher :
Elsevier BV, 2018.

Abstract

CAD-CAM patient-specific implants offer cerebral protection and improved facial balance without the disadvantages of autologous bone grafting such as donor site morbidity and unpredictable resorption. Several alloplastic materials are available, but titanium, polymethylmethacrylate (PMMA), and polyetheretherketone (PEEK) are the current popular choices. We reviewed our experience of applying different alloplastic CAD-CAM materials in the reconstruction of complex pediatric craniofacial deformities.A retrospective review was performed of all pediatric patients who underwent a complex inlay or onlay implant craniofacial reconstruction using CAD-CAM PEEK, PMMA, or titanium implants at a single institution. Demographics, cost, operative time, complications, and outcomes were assessed.Between 2003 and 2014, 136 patients (69 male; 67 female; mean age 11.5 years (3-22 years); mean follow-up 30 months) had custom patient-specific craniofacial reconstruction with PEEK (n = 72), PMMA (n = 42), and titanium (n = 22) implants (inlay = 93; onlay = 43). Indications included congenital anomalies (26.5%), decompressive craniectomies (25.0%), craniofacial syndromes (25.7%), tumor defects (14.0%), and post-trauma (6.6%). Implant cost varied significantly for PEEK ($7703 CAD) and PMMA ($8328 CAD) compared with that for titanium ($11,980 CAD) (p 0.0005). Six patients (4.4%) required surgery due to infection consisting of irrigation and antibiotic administration with successful implant salvage in three patients. All infections occurred in the PEEK group. Five patients (3.7%) ultimately had implants removed due to infection (n = 3), late exposure (titanium; n = 1), or late fracture (PMMA; n = 1).CAD-CAM alloplast reconstruction in the management of complex pediatric craniofacial deformities is effective although expensive. Implant infection does not always require explantation. A reconstruction algorithm is presented.

Details

ISSN :
17486815
Volume :
71
Database :
OpenAIRE
Journal :
Journal of Plastic, Reconstructive & Aesthetic Surgery
Accession number :
edsair.doi.dedup.....80ac4f33a1a84329d9ae048d5773fe40
Full Text :
https://doi.org/10.1016/j.bjps.2018.07.016