Back to Search
Start Over
Measurement of specific radioactivity by high-performance liquid chromatograph with a synchronized accumulating radioisotope detector: Determination of turnover rate and pool size of tryptophan in rat
- Source :
- Analytical Biochemistry. 173:196-200
- Publication Year :
- 1988
- Publisher :
- Elsevier BV, 1988.
-
Abstract
- A high-performance liquid chromatograph with a synchronized accumulating radioisotope detector was used to determine the turnover rate and pool size of tryptophan in rat. The specific radioactivity could be followed for three half-lives on the final slope of the specific radioactivity curve following intravenous administration of 15 muCi of carrier free tryptophan labeled with carbon-14. Remarkable individual differences were noted in turnover rate and in pool size among rats.