Predictability of Refractive Outcome of a Small-Aperture Intraocular Lens in Eyes With Irregular Corneal Astigmatism
- Source :
- Journal of refractive surgery (Thorofare, N.J. : 1995). 37(5)
- Publication Year :
- 2021
-
Abstract
- PURPOSE: To compare different new-generation biometric formulas and ray-tracing for small-aperture intraocular lens (IOL) (IC-8; Acufocus, Inc) implantation in patients undergoing cataract and refractive lens exchange surgery with highly irregular corneas. METHODS: This monocenter study included 17 eyes of 17 patients with highly irregular corneas of different genesis. Biometric and topographic corneal data were assessed using the IOLMaster 700 (Carl Zeiss Meditec) and Pentacam (Oculus Optkigeräte GmbH). Prediction and absolute error were compared after 3 months based on manifest refraction. Furthermore, change of total corneal refractive power in different corneal pathologies was also evaluated. For IOL power calculation, three fourth-generation IOL formulas were compared (Haigis, SRK-T, and Barrett Universal II). The dataset was then checked against ray-tracing and analyzed to improve prediction error in these highly irregular corneas. RESULTS: All patients showed an improvement in visual acuity postoperatively with a mean spherical equivalent of −1.22 ± 0.49 diopters (D). Overall comparison of the three formulas showed the Haigis formula to be superior in terms of the smallest deviation of predictive and absolute error. IOL calculations with ray-tracing were possible in all eyes, but showed inaccurate results with keratometric values of 48.00 D and greater. CONCLUSIONS: The IC-8 IOL is well suited for patients with lens exchange in highly irregular corneas. The Haigis formula seemed to be the most accurate in the patient group. Ray-tracing confirmed the results of biometric formulas up to a keratometric value of 48.00 D and should be compared with standard biometric formulas to address corneal irregularities and to minimize refractive surprises after surgery. A comparison with ray-tracing in eyes with a keratometric value of greater than 48.00 D should not be considered due to the inaccurate results. [ J Refract Surg . 2021;37(5):312–317.]
- Subjects :
- medicine.medical_specialty
Optics and Photonics
Visual acuity
Biometry
genetic structures
medicine.medical_treatment
Mean squared prediction error
Intraocular lens
Refraction, Ocular
Cornea
03 medical and health sciences
0302 clinical medicine
Lens Implantation, Intraocular
Ophthalmology
medicine
Humans
In patient
Patient group
Dioptre
Mathematics
Retrospective Studies
Lenses, Intraocular
Phacoemulsification
Astigmatism
Large aperture
eye diseases
030221 ophthalmology & optometry
Surgery
sense organs
medicine.symptom
Corneal astigmatism
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 1081597X
- Volume :
- 37
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Journal of refractive surgery (Thorofare, N.J. : 1995)
- Accession number :
- edsair.doi.dedup.....83c3a230782e392954f5c01733ad7da8