Back to Search
Start Over
Reformulated McNamara RBE-weighted beam orientation optimization for intensity modulated proton therapy
- Source :
- Med Phys, Medical physics, vol 49, iss 4
- Publication Year :
- 2022
-
Abstract
- PurposeEmpirical relative biological effectiveness (RBE) models have been used to estimate the biological dose in proton therapy but do not adequately capture the factors influencing RBE values for treatment planning. We reformulate the McNamara RBE model such that it can be added as a linear biological dose fidelity term within our previously developed sensitivity-regularized and heterogeneity-weighted beam orientation optimization (SHBOO) framework.MethodsBased on our SHBOO framework, we formulated the biological optimization problem to minimize total McNamara RBE dose to OARs. We solve this problem using two optimization algorithms: FISTA (McNam-FISTA) and Chambolle-Pock (McNam-CP). We compare their performances with a physical dose optimizer assuming RBE=1.1 in all structures (PHYS-FISTA) and an LET-weighted dose model (LET-FISTA). Three head and neck patients were planned with the four techniques and compared on dosimetry and robustness.ResultsCompared to Phys-FISTA, McNam-CP was able to match CTV [HI, Dmax, D95%, D98%] by [0.00, 0.05%, 1.4%, 0.8%]. McNam-FISTA and McNam-CP were able to significantly improve overall OAR [Dmean, Dmax] by an average of [36.1%,26.4%] and [29.6%, 20.3%], respectively. Regarding CTV robustness, worst [Dmax, V95%, D95%, D98%] improvement of [-6.6%, 6.2%, 6.0%, 4.8%] was reported for McNam-FISTA and [2.7%, 2.7%, 5.3%, -4.3%] for McNam-CP under combinations of range and setup uncertainties. For OARs, worst [Dmax, Dmean] were improved by McNam-FISTA and McNam-CP by an average of [25.0%, 19.2%] and [29.5%, 36.5%], respectively. McNam-FISTA considerably improved dosimetry and CTV robustness compared to LET-FISTA, which achieved better worst-case OAR doses.ConclusionThe four optimization techniques deliver comparable biological doses for the head and neck cases. Besides modest CTV coverage and robustness improvement, OAR biological dose and robustness were substantially improved with both McNam-FISTA and McNam-CP, showing potential benefit for directly incorporating McNamara RBE in proton treatment planning.
- Subjects :
- Organs at Risk
RBio-particle therapy-protons
Radiotherapy
Radiotherapy Planning, Computer-Assisted
Radiotherapy Planning
Oncology and Carcinogenesis
Biomedical Engineering
RBE
Radiotherapy Dosage
General Medicine
Article
proton therapy-dose optimization
Other Physical Sciences
Nuclear Medicine & Medical Imaging
Computer-Assisted
Clinical Research
Intensity-Modulated
Proton Therapy
Humans
Radiotherapy, Intensity-Modulated
Relative Biological Effectiveness
Cancer
Subjects
Details
- ISSN :
- 24734209
- Volume :
- 49
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Medical physicsREFERENCES
- Accession number :
- edsair.doi.dedup.....86c23df5ac7367c1ce2367c396a14801