Back to Search Start Over

Identification of Clinical Biomarkers for Pre-Analytical Quality Control of Blood Samples

Authors :
Ji Young Yun
Jun-Woo Kim
Bok Ghee Han
Hyun Ju Kang
Mee-Hee Lee
Soon Young Jeon
Won Kyung Hong
Jae-Pil Jeon
Jae-Sun Park
Han Na Kil
Source :
Biopreservation and Biobanking. 11:94-100
Publication Year :
2013
Publisher :
Mary Ann Liebert Inc, 2013.

Abstract

Pre-analytical conditions are key factors in maintaining the high quality of biospecimens. They are necessary for accurate reproducibility of experiments in the field of biomarker discovery as well as achieving optimal specificity of laboratory tests for clinical diagnosis. In research at the National Biobank of Korea, we evaluated the impact of pre-analytical conditions on the stability of biobanked blood samples by measuring biochemical analytes commonly used in clinical laboratory tests.We measured 10 routine laboratory analytes in serum and plasma samples from healthy donors (n = 50) with a chemistry autoanalyzer (Hitachi 7600-110). The analyte measurements were made at different time courses based on delay of blood fractionation, freezing delay of fractionated serum and plasma samples, and at different cycles (0, 1, 3, 6, 9) of freeze-thawing. Statistically significant changes from the reference sample mean were determined using the repeated-measures ANOVA and the significant change limit (SCL).The serum levels of GGT and LDH were changed significantly depending on both the time interval between blood collection and fractionation and the time interval between fractionation and freezing of serum and plasma samples. The glucose level was most sensitive only to the elapsed time between blood collection and centrifugation for blood fractionation. Based on these findings, a simple formula (glucose decrease by 1.387 mg/dL per hour) was derived to estimate the length of time delay after blood collection. In addition, AST, BUN, GGT, and LDH showed sensitive responses to repeated freeze-thaw cycles of serum and plasma samples.These results suggest that GGT and LDH measurements can be used as quality control markers for certain pre-analytical conditions (eg, delayed processing or repeated freeze-thawing) of blood samples which are either directly used in the laboratory tests or stored for future research in the biobank.

Details

ISSN :
19475543 and 19475535
Volume :
11
Database :
OpenAIRE
Journal :
Biopreservation and Biobanking
Accession number :
edsair.doi.dedup.....87611e419eb88407826ef5efaf23e118
Full Text :
https://doi.org/10.1089/bio.2012.0051