Back to Search
Start Over
Correction: Electroretinograms recorded with skin electrodes in silicone oil-filled eyes
- Source :
- PLoS ONE, PLoS ONE, Vol 14, Iss 5, p e0216823 (2019)
- Publication Year :
- 2019
- Publisher :
- Public Library of Science (PLoS), 2019.
-
Abstract
- PurposeTo assess the physiology of the retina by electroretinography (ERG) with skin electrodes in eyes that had undergone vitrectomy with silicone oil (SO) tamponade.DesignRetrospective case series.MethodERGs were recorded from eleven eyes with complex vitreoretinal disorders and from the normal fellow eyes. The affected eyes underwent pars plana vitrectomy (PPV) with SO tamponade. ERGs were recorded before and after the SO was removed. The amplitudes and implicit times of the a- and b-waves of the affected eyes were compared to those of the normal fellow eyes. In addition, the ratios of the amplitudes of the b-waves of the affected eyes to those of the fellow eyes were compared before and after the SO was removed.ResultsERGs were recordable from 7 eyes (63.6%) before the SO was removed and 11 eyes (100%) after the SO was removed. The a- and b-wave amplitudes were significantly smaller in the affected eyes than those of the fellow eyes at the baseline. The b-wave amplitude before the removal of the SO was significantly and positively correlated with that after the SO removal. The ratios of the b-waves of the affected/normal fellow eye significantly increased after the SO was removed.ConclusionThe results indicate that ERGs picked up by skin electrode can be used to assess the physiology of the retina in eyes with a SO tamponade. The amplitude of the b-waves of the ERGs in silicone-filled eyes can be used to predict the amplitude after the silicone is removed.
- Subjects :
- Male
Skin Physiology
0301 basic medicine
Eye Diseases
genetic structures
Physiology
medicine.medical_treatment
Skin physiology
Silicones
Electrode Recording
Vitrectomy
Biochemistry
chemistry.chemical_compound
0302 clinical medicine
Medicine and Health Sciences
Silicone Oils
Membrane Electrophysiology
Skin
Multidisciplinary
medicine.diagnostic_test
Retinal detachment
Middle Aged
Lipids
Silicone oil
Electrophysiology
Chemistry
Bioassays and Physiological Analysis
medicine.anatomical_structure
Physical Sciences
Medicine
Retinal Disorders
Female
Tamponade
Anatomy
Integumentary System
Research Article
Pars plana
medicine.medical_specialty
Science
Ocular Anatomy
Research and Analysis Methods
Retina
03 medical and health sciences
Ocular System
Ophthalmology
Electroretinography
medicine
Humans
Electrodes
Aged
Retrospective Studies
business.industry
Electrophysiological Techniques
Chemical Compounds
Retinal Detachment
Correction
Biology and Life Sciences
medicine.disease
eye diseases
Skin electrode
030104 developmental biology
chemistry
030221 ophthalmology & optometry
Eyes
sense organs
business
Head
Oils
Subjects
Details
- ISSN :
- 19326203
- Volume :
- 14
- Database :
- OpenAIRE
- Journal :
- PLOS ONE
- Accession number :
- edsair.doi.dedup.....876314f09d2c00e3c1008e2f729f0ed2
- Full Text :
- https://doi.org/10.1371/journal.pone.0216823