Back to Search
Start Over
Validation Experiments on the 2-MW CW 170-GHz Load for the European ITER Gyrotron
- Source :
- IEEE transactions on plasma science 45 (2017): 501. doi:10.1109/TPS.2017.2658184, info:cnr-pdr/source/autori:Bin W.; Bruschi A.; Takahashi K.; Ikeda R.; Oda Y.; Aoki T.; Dell'Era F.; Hayashibara M.; Minelli D.; Nardone A.; Sakamoto K.; Simonetto A.; Spinicchia N.; Terakado M.; Tsubota N./titolo:Validation Experiments on the 2-MW CW 170-GHz Load for the European ITER Gyrotron/doi:10.1109%2FTPS.2017.2658184/rivista:IEEE transactions on plasma science/anno:2017/pagina_da:501/pagina_a:/intervallo_pagine:501/volume:45
- Publication Year :
- 2017
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2017.
-
Abstract
- The development of high-power gyrotrons needs matched loads with good performance capable of absorbing and measuring powers as high as 1 MW in the International Thermonuclear Experimental Reactor (ITER) and higher (up to two times) in the future devices, such as the DEMOnstrating fusion power reactor. At Istituto di Fisica del Plasma - Consiglio Nazionale delle Ricerche IFP-CNR (Milan), several spherical loads were developed, all with identical absorbing geometry but different heat removal systems for operations with pulselengths (PLs) from a few milliseconds to continuous wave (CW). A dummy load designed for 2-MW CW 170-GHz operations has been constructed in the frame of the development program of the European gyrotron for ITER. The first prototype hemisphere of this load, joined with an uncoated one, has been successfully tested with long pulses and under vacuum using the gyrotron for ITER of the National Institutes for Quantum and Radiological Science and Technology in Naka. The symmetry of the system is such that the equivalent power (EP) load of the absorbing (coated) hemisphere is doubled when the second one is reflective (uncoated), with an almost unchanged distribution with respect to a fully coated load. The tests demonstrate the capability of the IFP-CNR load to withstand and measure radiation at an EP in an excess of 1.5MW. Experiments involving gyrotron pulses with increasing power and PL have been performed in the load and are reported. The maximum EP load reached in the tests was $\approx 1.8$ MW for 15 s while the longest pulse was 300 s, at $\approx 1$ MW. During the experiments, the temperatures of either the load or the preload were monitored using thermocouples and multiple infrared cameras, while a pressure sensor and a hydrophone have been used for the monitoring of cavitation phenomena and water boiling in the cooling circuits. The results achieved in the tests are described in this paper.
- Subjects :
- Dummy load
Nuclear and High Energy Physics
gyrotron
Thermonuclear fusion
Materials science
business.industry
Nuclear engineering
Electrical engineering
Fusion power
Condensed Matter Physics
01 natural sciences
Pressure sensor
matched load
010305 fluids & plasmas
law.invention
Continuous wave (CW) operations
law
Thermocouple
Gyrotron
0103 physical sciences
Continuous wave
010306 general physics
business
Electronic circuit
Subjects
Details
- ISSN :
- 19399375 and 00933813
- Volume :
- 45
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Plasma Science
- Accession number :
- edsair.doi.dedup.....8772f8f1f1b5a5fcca4b90e7447c0877
- Full Text :
- https://doi.org/10.1109/tps.2017.2658184