Back to Search Start Over

Calibration of the Pierre Auger fluorescence detector

Authors :
Roberts, M.
Ave, M.
Letessier, A.
Bertou, X.
Deligny, O.
Lachaud, C.
Altmann, E.
Alvarez, P.
Bauleo, P.
Bonifazi, C.
Etchegoyen, A.
Eusebi, R.
Fazzini, N.
Ferrero, A.
Filevich, A.
Reguera, A.
Cillis, A.
Dova, M. T.
Epele, L. N.
Grunfeld, C.
Mariazzi, A.
Martinez, N.
Roulet, E.
Sciutto, S. J.
Veiga, A.
Allekotte, I.
Avila, G.
Masperi, L.
Orsaria, M.
Rovero, A.
Clay, R. W.
Dawson, B. R.
Pace, R.
Riordan, D.
Thornton, G. J.
Wild, N. R.
Boutonnet, C.
Brunet, J. M.
Capdevielle, J. N.
Cohen, F.
Courty, B.
Guglielmi, L.
Jaeger, J. J.
Benoît Revenu
Tristram, G.
Waisbard, J.
Billoir, P.
Boratav, M.
Castera, A.
Sylvie DAGORET
Genolini, B.
Lefebvre, F.
Lhenry-Yvon, I.
Trung, T. N.
Parizot, E.
Pouthas, J.
Suomijarvi, T.
Albert, J. N.
Arnault, C.
Bilhaut, R.
Cordier, A.
Cormier, E.
Eschstruth, P.
Jouniaux, O.
Lavigne, B.
Oleg Lodygensky
Rypko, J.
Martin Urban
Bluemer, H.
Bollmann, E.
Csabo, T.
Grindler, A.
Gumbsheimer, R.
Heck, D.
Hucker, H.
Kern, H.
Klages, H. O.
Kleinfeller, J.
Mathes, H. J.
Matussek, P.
Michel-Piper, I.
Risse, M.
Schleif, G.
Thouw, T.
Balzer, M.
Berg, R.
Bormann, D.
Gemmeke, H.
Giraud, H.
Kleifges, M.
Kopmann, A.
Kunka, N.
Menchikov, A.
Osswald, B.
Remmel, U.
Tscherniakhovski, D.
Barenthien, N.
Kampert, K. H.
Keilhauer, B.
Argiro, S.
Camin, D. V.
Guerard, C.
Ambrosio, M.
Bernardini, C.
Facal, P.
Filosofi, R.
Fois, M.
Matthiae, G.
Privitera, P.
Salina, G.
Borreani, G.
Cester, R.
Menichetti, E.
Pastrone, N.
Aramo, C.
Cangiano, E.
Fonte, R.
Insolia, A.
Raia, G.
Gora, D.
Homola, P.
Kutschera, M.
Ostrowski, M.
Wilczynska, B.
Wilczynski, H.
Arcon, I.
Filipcic, A.
Zavrtanik, D.
Zavrtanik, M.
Clark, P.
Bruijn, L.
Knapp, J.
Lloyd-Evans, J.
Patel, M.
Tunnicliffe, V.
Walker, P.
Watson, A.
Arisaka, K.
Bonushkin, Y.
Kubic, J.
Slater, W.
Tripathi, A.
Brack, J.
Hofman, G.
Ristinen, R.
Harton, J.
Sites, J.
Warner, D.
Wilson, R.
Cronin, J. W.
Gibbs, K.
Albrow, M.
Andrews, R.
Berman, E.
Hoffer, D.
Glass, H.
Hojvat, C.
Mantsch, P.
Mazur, P.
Spinka, H.
Voyvodic, L.
Matthews, J. M.
Mcewen, M.
Meyhandan, R.
Darling, J.
Dorofeev, A.
Nemiroff, B.
Nitz, D.
Rafert, B.
Ruotsala, S.
Szadkowski, Z.
Trombley, M.
Dieterle, B.
Matthews, J.
Riley, S.
Allison, P.
Beatty, J.
Coutu, S.
Duvernois, M.
Cassiday, G.
Fick, B.
Sommers, P.
Luis. Anchordoqui
Machacek, M.
Paul, T.
Swain, J.
Taylor, L.
Akhperjanian, A.
Chilingarian, A.
Hovsepian, G.
Mnatzakanian, E.
Sahakian, V.
Ter-Antonian, S.
Aguirre, C.
Bustos, R.
Choque, K.
Ticona, A.
Ticona, R.
Velarde, A.
Thieu, D. Q.
Darriulat, P.
Chung, N.
Dzung, N. T.
Dinh, P. N.
Phuong, P. T.
Thuan, V. V.
Physique Corpusculaire et Cosmologie - Collège de France (PCC)
Collège de France (CdF (institution))-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Institut de Physique Nucléaire d'Orsay (IPNO)
Université Paris-Sud - Paris 11 (UP11)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)
Kajita T. Asaoka Y. Kawachi A. Matsubara M. Sasaki M.
PIERRE AUGER
Centre National de la Recherche Scientifique (CNRS)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Université Paris-Sud - Paris 11 (UP11)
Source :
28th International Cosmic Ray Conference, International Cosmic Ray Conference 28 ICRC 2003, International Cosmic Ray Conference 28 ICRC 2003, Jul 2003, Tsukuba, Japan. pp.453-456, HAL
Publication Year :
2003
Publisher :
arXiv, 2003.

Abstract

The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates the flux of photons of a given wavelength at the detector aperture to the electronic signal recorded by the FD data acquisition system. For the Auger FDs, the primary absolute calibration method uses a diffusive surface which is placed in front of a telescope aperture to uniformly illuminate the telescope field of view with a known light signal. This single-wavelength measurement (375 nm) will be made at intervals of several months until the stability of the telescopes is determined. The relative wavelength dependence of the calibration is determined through independent measurements. The error in absolute calibration at a single wavelength is estimated to be less than 10%. Two other absolute calibration methods are used to provide an independent verification of the primary measurement. The stability of the calibration with time is monitored nightly by a relative calibration system. In this paper we will provide descriptions of the absolute and relative calibration methods used by the Auger air fluorescence observatory. Results from the calibration of the Auger Engineering Array telescopes will also be presented.<br />Comment: 4 pages, no figures. Presented at the 28th International Cosmic Ray Conference

Details

Database :
OpenAIRE
Journal :
28th International Cosmic Ray Conference, International Cosmic Ray Conference 28 ICRC 2003, International Cosmic Ray Conference 28 ICRC 2003, Jul 2003, Tsukuba, Japan. pp.453-456, HAL
Accession number :
edsair.doi.dedup.....8a00634796797ed0d31595fe9e8d58cd
Full Text :
https://doi.org/10.48550/arxiv.astro-ph/0308410