Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples
- Source :
- E-Prints Complutense. Archivo Institucional de la UCM, instname
- Publication Year :
- 2022
- Publisher :
- Wiley-VCH, 2022.
-
Abstract
- The development of two different immunoassays for the determination of fumonisin B1 in wheat samples is reported. A previously described mimopeptide for fumonisin B1 (FB1) was used to produce fusion proteins in combination with two different luciferases: Gaussia luciferase (GLuc) and NanoLuc luciferase (NLuc). The production, expression and the development of two immunoassays based on these fusion proteins (A2- GLuc and A2-NLuc) is detailed. The assay showing the best performance, A2-NLuc, with a limit of detection of 0.61 ngmL 1 and a dynamic range from 1.9 to 95 ngmL 1 , was employed for the analysis of spiked wheat samples, a reference matrix material, as well as naturally contaminated wheat samples. The recoveries obtained in the spiked samples were acceptable, between 81.5 and 109%, with relative standard deviations lower than 14%. The analysis of naturally contaminated wheat was validated by a liquid chromatography coupled to tandem mass detection method.
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- E-Prints Complutense. Archivo Institucional de la UCM, instname
- Accession number :