Back to Search Start Over

Rapid detection of isthmus block and rhythm change using local electrogram changes during complex atrial flutter ablation

Authors :
Benzy J Padanilam
Sarah W Whittam
Brad A Clark
Jeffrey A Olson
Girish V Nair
Sandeep A Joshi
Eric N Prystowsky
Parin J Patel
Jasen L Gilge
Source :
EP Europace. 25:756-761
Publication Year :
2022
Publisher :
Oxford University Press (OUP), 2022.

Abstract

Aims Multiple re-entry circuits may operate simultaneously in the atria in the form of dual loop re-entry using a common isthmus, or multiple re-entrant loops without a common isthmus. When two or more re-entrant circuits coexist, ablation of an individual isthmus may lead to a seamless transition (without significant changes in surface electrocardiogram, coronary sinus activation or tachycardia cycle length) to a second rhythm, and the isthmus block can go unnoticed. Methods and results We hypothesize and subsequently illustrate in three patient cases, methods to rapidly identify a transition in the rhythm and isthmus block using local electrogram changes at the ablation site. Conclusion Local activation sequence changes, electrogram timing, and the behaviour of pre-existing double potentials can reveal isthmus block promptly when rhythm transitions occur during ablation of multiloop re-entry tachycardias.

Details

ISSN :
15322092 and 10995129
Volume :
25
Database :
OpenAIRE
Journal :
EP Europace
Accession number :
edsair.doi.dedup.....8acc25f88ce550787237c1eb38d02c15
Full Text :
https://doi.org/10.1093/europace/euac161