Back to Search
Start Over
Direct comparison between 2-dimensional and 3-dimensional PET acquisition modes for myocardial blood flow absolute quantification with O-15 water and N-13 ammonia
- Source :
- Journal of Nuclear Cardiology. 13:220-224
- Publication Year :
- 2006
- Publisher :
- Springer Science and Business Media LLC, 2006.
-
Abstract
- BACKGROUND: Positron emission tomography scanners with retractable septa allow both 3-dimensional (3D) and 2-dimensional (2D) acquisition modes. The study aim was to directly compare 2D and 3D acquisition modes for the evaluation of absolute myocardial blood flow (MBF) over a wide range of flow values. METHODS AND RESULTS: Instrumentation was used in 4 dogs to reduce the left circumflex artery lumen by greater than 75%. During infusion of adenosine, MBF was measured with both 2D and 3D dynamic acquisition and both oxygen 15 water and nitrogen 13 ammonia. Injected activities were 333 MBq and 111 MBq for 2D acquisition and 3D acquisition, respectively. Data were reconstructed by analytic methods, and MBF was assessed by use of an 18-segment model. MBF values ranged from 0.4 to 5.8 mL x g(-1) x min(-1) with O-15 water and from 0.3 to 3.9 mL x g(-1) x min(-1) with N-13 ammonia. No significant differences were observed in absolute MBF values obtained with the 2 acquisition modes, regardless of the flow tracer used. Two-dimensionally and three-dimensionally derived MBF values were significantly strongly correlated by use of both O-15 water (y = 0.98x + 0.18, r = 0.87, P < .001) and N-13 ammonia (y = 0.99x + 0.09, r = 0.95, P < .001). CONCLUSION: Quantification of MBF in dogs with 3D positron emission tomography provides results similar to those obtained with the 2D technique, despite a lower activity being injected.
- Subjects :
- Absolute quantification
Flow tracer
Left circumflex artery
Sensitivity and Specificity
Coronary circulation
Dogs
Nuclear magnetic resonance
Ammonia
Oxygen Radioisotopes
Coronary Circulation
Animals
Medicine
Radiology, Nuclear Medicine and imaging
N 13 ammonia
Lower activity
Nitrogen Radioisotopes
medicine.diagnostic_test
business.industry
Reproducibility of Results
Water
Blood flow
Coronary Vessels
medicine.anatomical_structure
Positron emission tomography
Positron-Emission Tomography
Radiopharmaceuticals
Cardiology and Cardiovascular Medicine
business
Nuclear medicine
Blood Flow Velocity
circulatory and respiratory physiology
Subjects
Details
- ISSN :
- 15326551 and 10713581
- Volume :
- 13
- Database :
- OpenAIRE
- Journal :
- Journal of Nuclear Cardiology
- Accession number :
- edsair.doi.dedup.....8aef270dca6c5cacb43904df74c50612
- Full Text :
- https://doi.org/10.1007/bf02971246