Back to Search
Start Over
Accuracy of device landing zone calcium volume measurement with contrast-enhanced multidetector computed tomography
- Source :
- International Journal of Cardiology. 263:171-176
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- Background The extent of aortic valve calcification is an important determinant of procedural success in transcatheter aortic valve implantation (TAVI). We sought to validate device landing zone calcium volume (DLZ-CV) measurements on contrast-enhanced multidetector computed tomography (MDCT) with non-contrast-enhanced scans as reference. Methods We determined DLZ-CV in 141 patients undergoing transfemoral TAVI. Non-contrast-enhanced images were analyzed using a threshold of 130 HU as reference (DLZ-CV130). For contrast-enhanced scans, we applied various thresholds including 450 HU (DLZ-CV450), 850 HU (DLZ-CV850), mean aortic attenuation (AttenAo) + 2 SD (DLZ-CV2SD), AttenAo + 4 SD (DLZ-CV4SD), AttenAo + 4 SD + 5 mm3 volume filter (DLZ-CV4SD+), and based on visual estimation (DLZ-CVvis). We compared DLZ-CV values between patients with versus without paravalvular leak (PVL), and between patients with versus without post-dilatation stratified by the type of prosthesis. Results All DLZ-CV measurements on contrast-enhanced scans significantly differed from DLZ-CV130 (p Conclusion Measurement of DLZ-CV using contrast-enhanced scans with unadjusted thresholds results in incorrect estimation of the calcium volume. The use of a scan-specific individual HU threshold including a volume filter (DLZ-CV4SD+) provides the best approximation to the reference and allows for discrimination of PVL ≥ 1° in patients receiving the Acurate neo prosthesis.
- Subjects :
- Male
media_common.quotation_subject
medicine.medical_treatment
Contrast Media
Calcium volume
030204 cardiovascular system & hematology
Prosthesis
Transcatheter Aortic Valve Replacement
03 medical and health sciences
0302 clinical medicine
Hounsfield scale
Multidetector Computed Tomography
Multidetector computed tomography
medicine
Humans
Contrast (vision)
030212 general & internal medicine
Aged
Retrospective Studies
media_common
Aged, 80 and over
business.industry
Aortic Valve Stenosis
medicine.disease
Landing zone
Aortic valve stenosis
Calcium
Female
Aortic valve calcification
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Subjects
Details
- ISSN :
- 01675273
- Volume :
- 263
- Database :
- OpenAIRE
- Journal :
- International Journal of Cardiology
- Accession number :
- edsair.doi.dedup.....8b0e00fe1d8f5c19c723e40d7f01bbf7
- Full Text :
- https://doi.org/10.1016/j.ijcard.2018.02.042