Back to Search
Start Over
Biomechanical analysis of intramedullary vs. superior plate fixation of transverse midshaft clavicle fractures
- Source :
- Journal of Shoulder and Elbow Surgery. 25:949-953
- Publication Year :
- 2016
- Publisher :
- Elsevier BV, 2016.
-
Abstract
- Background Middle-third clavicle fractures represent 2% to 4% of all skeletal trauma in the United States. Treatment options include intramedullary (IM) as well as plate and screw (PS) constructs. The purpose of this study was to analyze the biomechanical stability of a specific IM system compared with nonlocking PS fixation under low-threshold physiologic load. Methods Twenty fourth-generation Sawbones (Pacific Research Laboratories, Vashon, WA, USA) with a simulated middle-third fracture pattern were repaired with either an IM device (n = 10) or superiorly positioned nonlocking PS construct (n = 10). Loads were modeled to simulate physiologic load. Combined axial compression and torsion forces were sequentially increased until failure. Data were analyzed on the basis of loss of rotational stability using 3 criteria: early (10°), clinical (30°), and terminal (120°). Results No significant difference was noted between constructs in early loss of rotational stability (P > .05). The PS group was significantly more rotationally stable than the IM group on the basis of clinical and terminal criteria (P Conclusions When tested under physiologic load, fixation failure occurred from loss of rotational stability. No statistical difference was seen between groups under early physiologic loads. However, during load to failure, the PS group was statistically more rotationally stable than the IM group. Given the clavicle's function as a bony strut for the upper extremity and the biomechanical results demonstrated, rotational stability should be carefully considered during surgical planning and postoperative advancement of activity in patients undergoing operative fixation of middle-third clavicle fractures. Level of evidence Basic Science Study; Biomechanics
- Subjects :
- Models, Anatomic
medicine.medical_specialty
Rotation
Bone Screws
Bone Nails
Surgical planning
law.invention
Intramedullary rod
Fractures, Bone
03 medical and health sciences
Fixation (surgical)
0302 clinical medicine
law
Load to failure
Humans
Medicine
Orthopedics and Sports Medicine
030212 general & internal medicine
Plate fixation
030222 orthopedics
business.industry
Biomechanics
General Medicine
Clavicle
Biomechanical Phenomena
Fracture Fixation, Intramedullary
Surgery
Transverse plane
medicine.anatomical_structure
Diaphyses
business
Bone Plates
Subjects
Details
- ISSN :
- 10582746
- Volume :
- 25
- Database :
- OpenAIRE
- Journal :
- Journal of Shoulder and Elbow Surgery
- Accession number :
- edsair.doi.dedup.....8b5f966c01d37a3a2197d0d2c9b519db