Back to Search
Start Over
Quality of life and healthcare utilisation improvements after atrial fibrillation ablation
- Source :
- Heart, Gupta, D, Vijgen, J, Potter, T D, Scherr, D, Van Herendael, H, Knecht, S, Kobza, R, Berte, B, Sandgaard, N, Albenque, J P, Széplaki, G, Stevenhagen, Y, Taghji, P, Wright, M & Duytschaever, M 2021, ' Quality of life and healthcare utilisation improvements after atrial fibrillation ablation ', Heart, vol. 107, no. 16, pp. 1296-1302 . https://doi.org/10.1136/heartjnl-2020-318676
- Publication Year :
- 2021
- Publisher :
- BMJ, 2021.
-
Abstract
- ObjectivePulmonary vein isolation (PVI) guided by a standardised CLOSE (contiguous optimised lesions) protocol has been shown to increase clinical success after catheter ablation for paroxysmal atrial fibrillation (PAF). This study analysed healthcare utilisation and quality of life (QOL) outcomes from a large multicentre prospective study, measured association between QOL and atrial fibrillation (AF) burden and identified factors associated with lack of QOL improvement.MethodsCLOSE-guided ablation was performed in 329 consecutive patients (age 61.4 years, 60.8% male) with drug-refractory PAF in 17 European centres. QOL was measured at baseline and 12 months post-ablation via Atrial Fibrillation Effect on QualiTy of Life Survey (AFEQT) and EuroQoL EQ-5D-5L questionnaires. All-cause and cardiovascular hospitalisations and cardioversions over 12 months pre-ablation and post-ablation were recorded. Rhythm monitoring included weekly and symptom-driven trans-telephonic monitoring, plus ECG and Holter monitoring at 3, 6 and 12 months. AF burden was defined as the percentage of postblanking tracings with an atrial tachyarrhythmia ≥30 s. Continuous measures across multiple time points were analysed using paired t-tests, and associations between various continuous measures were analysed using independent sample t-tests. Each statistical test used two-sided p values with a significance level of 0.05.ResultsBoth QOL instruments showed significant 12-month improvements across all domains: AFEQT score increased 25.1–37.5 points and 33.3%–50.8% fewer patients reporting any problem across EuroQoL EQ-5D-5L domains. Overall, AFEQT improvement was highly associated with AF burden (p=0.009 for 2DS2-VASc scores at baseline, and higher AF burden following PVI.ConclusionsQOL improved and healthcare utilisation decreased significantly after ablation with a standardised CLOSE protocol. QOL improvement was significantly associated with impairment at baseline and AF burden after ablation.Trial registration numberNCT03062046.
- Subjects :
- Male
medicine.medical_specialty
medicine.medical_treatment
Electric Countershock
Catheter ablation
Pulmonary vein
Cost of Illness
Quality of life
Surveys and Questionnaires
Internal medicine
Statistical significance
Atrial Fibrillation
Outcome Assessment, Health Care
catheter ablation
medicine
Humans
atrial fibrillation
Arrhythmias and Sudden Death
Perioperative Period
Prospective cohort study
business.industry
Atrial fibrillation
Middle Aged
Patient Acceptance of Health Care
medicine.disease
Ablation
Europe
Hospitalization
Pulmonary Veins
Electrocardiography, Ambulatory
Quality of Life
Female
Cardiology and Cardiovascular Medicine
Cardioversions
business
Subjects
Details
- ISSN :
- 1468201X and 13556037
- Volume :
- 107
- Database :
- OpenAIRE
- Journal :
- Heart
- Accession number :
- edsair.doi.dedup.....8b8b692efc478bb2ff7136b09d641b38
- Full Text :
- https://doi.org/10.1136/heartjnl-2020-318676