Back to Search
Start Over
Effect of system variables involved in packed column supercritical fluid chromatography of stavudine taken as model analyte using response surface methodology along with study of thermodynamic parameters
- Source :
- Journal of Pharmaceutical and Biomedical Analysis. 43:471-480
- Publication Year :
- 2007
- Publisher :
- Elsevier BV, 2007.
-
Abstract
- A multifactor optimization technique is successfully applied to study the effect of simultaneously varying the system variables on feasibility of stavudine analysis by packed column supercritical fluid chromatography (PC-SFC). The effect of simultaneously varying the pressure, temperature and modifier concentration was studied to optimize the method in order to obtain excellent chromatographic figures of merit. The method is based on isocratic elution using methanol-modified supercritical carbon dioxide as the mobile phase at the flow rate of 3.0 ml/min through a JASCO Finepak SIL-5, ODS [C(18) (5 microm, 25 cm x 4.6 mm, i.d.)] column support using photodiode array detection. The optimal conditions were determined with the aid of the response surface methodology using 3(3) factorial designs. From the response surface graphs optimum regions were selected to be +1, -1, and +1 for temperature (60 degrees C), pressure (20 MPa) and percent modifier concentration (17.81%, v/v), respectively. Linearity dynamic range was found to be in the range of 2.0-150.0 microg/ml with significantly high value of correlation coefficient. The method was validated for precision, robustness and recovery to assess the viability of the established method. The chromatographic limit of detection and quantitation were 0.80 and 1.50 microg/ml respectively. The method has been successfully used to analyze commercial dosage form to assess the chromatographic performance of SFC system which was found to be 99.91%+/-1.62. The present work briefs the thermodynamic applications of PC-SFC with an emphasis on the results of stavudine. The foremost of such applications is the determination of solute diffusion coefficient in supercritical mobile phase by Taylor-Aris peak broadening technique.
- Subjects :
- Quality Control
Clinical Biochemistry
Analytical chemistry
Pharmaceutical Science
Capsules
High-performance liquid chromatography
Analytical Chemistry
Diffusion
Drug Discovery
Pressure
Technology, Pharmaceutical
Response surface methodology
Least-Squares Analysis
Spectroscopy
Detection limit
Packed bed
Analysis of Variance
Chromatography
Supercritical carbon dioxide
Molecular Structure
Chemistry
Methanol
Temperature
Reproducibility of Results
Chromatography, Supercritical Fluid
Factorial experiment
Carbon Dioxide
Silicon Dioxide
Supercritical fluid
Kinetics
Stavudine
Calibration
Linear Models
Solvents
Supercritical fluid chromatography
Reverse Transcriptase Inhibitors
Thermodynamics
Drug Contamination
Thymine
Subjects
Details
- ISSN :
- 07317085
- Volume :
- 43
- Database :
- OpenAIRE
- Journal :
- Journal of Pharmaceutical and Biomedical Analysis
- Accession number :
- edsair.doi.dedup.....8b98f8eefef29c072945f426fe940d23
- Full Text :
- https://doi.org/10.1016/j.jpba.2006.07.038