Back to Search
Start Over
Development of breath test for pneumoconiosis: a case-control study
- Source :
- Respiratory Research, Respiratory Research, Vol 18, Iss 1, Pp 1-8 (2017)
- Publication Year :
- 2017
- Publisher :
- BioMed Central, 2017.
-
Abstract
- Background Lipid peroxidation plays an important role in the pathogenesis of pneumoconiosis. Volatile organic compounds (VOCs) generated from lipid peroxidation might be used to detect pneumoconiosis. The objective of this study was to develop a breath test for pneumoconiosis. Methods A case-control study was designed. Breath and ambient air were analysed by gas chromatography/mass spectrometry. After blank correction to prevent contamination from ambient air, we used canonical discriminant analysis (CDA) to assess the discrimination accuracy and principal component analysis (PCA) to generate a prediction score. The prediction accuracy was calculated and validated using the International Classification of Radiographs of the Pneumoconiosis criteria combined with an abnormal pulmonary function test as a reference standard. We generated a receiver operator characteristic (ROC) curve and calculated the area under the ROC curve (AUC) to estimate the screening accuracy of the breath test. Results We enrolled 200 stone workers. After excluding 5 subjects with asthma and 16 subjects who took steroids or nonsteroidal anti-inflammatory drugs, a total of 179 subjects were used in the final analyses, which included 25 cases and 154 controls. By CDA, 88.8% of subjects were correctly discriminated by their exposure status and the presence of pneumoconiosis. After excluding the VOCs of automobile exhaust and cigarette smoking, pentane and C5-C7 methylated alkanes constituted the major VOCs in the breath of persons with pneumoconiosis. Using the prediction score generated from PCA, the ROC-AUC was 0.88 (95% CI = 0.80—0.95), and the mean ROC-AUC of 5-fold cross-validation was 0.90. The breath test had good accuracy for pneumoconiosis diagnosis. Conclusion The analysis of breath VOCs has potential in the screening of pneumoconiosis for its non-invasiveness and high accuracy. We suggest that a multi-centre study is warranted and that all procedures must be standardized before clinical application.
- Subjects :
- 0301 basic medicine
Adult
Male
medicine.medical_specialty
Lipid peroxidation
Gas Chromatography-Mass Spectrometry
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
Cigarette smoking
Internal medicine
Occupational Exposure
medicine
Humans
Breathomics
Asthma
Aged
lcsh:RC705-779
Breath test
Volatile Organic Compounds
Nonsteroidal
Receiver operating characteristic
medicine.diagnostic_test
business.industry
Pneumoconiosis
Research
Case-control study
lcsh:Diseases of the respiratory system
Middle Aged
medicine.disease
Surgery
Ambient air
030104 developmental biology
030228 respiratory system
chemistry
Breath Tests
Case-Control Studies
Female
business
Subjects
Details
- Language :
- English
- ISSN :
- 1465993X and 14659921
- Volume :
- 18
- Database :
- OpenAIRE
- Journal :
- Respiratory Research
- Accession number :
- edsair.doi.dedup.....8cf3bd150f78e8b59e7041096df94f7e