Back to Search Start Over

Inhibition of complement, neutrophil, and platelet activation by an anti-factor D monoclonal antibody in simulated cardiopulmonary bypass circuits

Authors :
Michael Fung
Maryann W. Mueller
Charles D. Fraser
Cecily R. Y. Sun
Akif Ündar
William N. C. Sun
Paul G. Loubser
William K. Vaughn
Source :
The Journal of Thoracic and Cardiovascular Surgery. 122(1):113-122
Publication Year :
2001
Publisher :
Elsevier BV, 2001.

Abstract

Objectives: Patients undergoing cardiopulmonary bypass frequently manifest generalized systemic inflammation and occasionally manifest serious multiorgan failure. Inflammatory responses of bypass are triggered by contact of blood with artificial surfaces of the bypass circuits, surgical trauma, and ischemia-reperfusion injury. We studied the effects of specific inhibition of the alternative complement cascade by using an anti-factor D monoclonal antibody (166-32) in extracorporeal circulation of human whole blood used as a simulated model of cardiopulmonary bypass. Methods: Five healthy blood donors were used in the study. Monoclonal antibody 166-32 was added to freshly collected, heparinized human blood recirculated in a pediatric cardiopulmonary bypass circuit at a final concentration of 18 μg/mL. An irrelevant monoclonal antibody was used as a negative control with the same donor blood in a parallel bypass circuit on the same day. Blood samples were collected at different time points during recirculation for measurement of activation of complement, neutrophils, and platelets by immunofluorocytometric methods and enzyme-linked immunosorbent assays. Results: Monoclonal antibody 166-32 inhibited the alternative complement activation and the production of Bb, C3a, sC5b-9, and C5a. Upregulation of CD11b on neutrophils and CD62P on platelets was also significantly inhibited by monoclonal antibody 166-32. This is consistent with the inhibition of the release of neutrophil-specific myeloperoxidase and elastase and platelet thrombospondin. The production of proinflammatory cytokine interleukin 8 was also suppressed by the antibody. Conclusions: The alternative complement cascade is predominantly activated during extracorporeal circulation. Anti-factor D monoclonal antibody 166-32 is effective in inhibiting the activation of complement, neutrophils, and platelets. Inhibition of the alternative complement pathway by targeting factor D could be useful in reducing systemic inflammation in patients undergoing cardiopulmonary bypass. J Thorac Cardiovasc Surg 2001;122:113-22

Details

ISSN :
00225223
Volume :
122
Issue :
1
Database :
OpenAIRE
Journal :
The Journal of Thoracic and Cardiovascular Surgery
Accession number :
edsair.doi.dedup.....8d0efe1024286807c509d5d17a899801
Full Text :
https://doi.org/10.1067/mtc.2001.114777