SPOT IL - Slow positron facility in Israel

Authors :
Or Hen
D. Dribin
S. May-Tal Beck
G. Erlichman
P. Or
Eliahu Cohen
E. Piasetzky
Dan Cohen
I. Sabo-Napadensky
Guy Ron
Hadar Steinberg
Massachusetts Institute of Technology. Department of Physics
Source :
Prof. Hen via Barbara Williams
Publication Year :
2019
Publisher :
AIP Publishing, 2019.

Abstract

A slow positron facility is being built in Israel, at the Hebrew University, for basic and applied research. It consists of a slow positron beam and a compact Positrons Annihilation Lifetime (PAL) spectrometer. The slow positron beam follows a traditional design, using a 22Na source, of about 40mCi, a Tungsten moderator and a unique grounded target cell, with positrons energy that can vary between 0.03 keV and 30 keV. The detection system will be comprised of High Purity Germanium and BaF2 detectors, facing each other, for low background Doppler Broadening (DB) measurements. The target cell is designed to allow a combined measurement of sample conductivity and DB, with the flexibility to add more detection options in the future. The compact PAL spectrometer includes two fast scintillation detectors read by a fast digitizer (DRS4), with a sampling rate of 5.12 GS/s. A dedicated software package was developed to emulate analogue data acquisition. Lifetime measurements were performed using a ∼25 µCi 22Na source. The time resolution was defined using a 60Co source, to be 180-200ps. First positron lifetime validation measurements of Ti resulted in positrons lifetime of 157 ± 4 ps, consistent with previously published values.A slow positron facility is being built in Israel, at the Hebrew University, for basic and applied research. It consists of a slow positron beam and a compact Positrons Annihilation Lifetime (PAL) spectrometer. The slow positron beam follows a traditional design, using a 22Na source, of about 40mCi, a Tungsten moderator and a unique grounded target cell, with positrons energy that can vary between 0.03 keV and 30 keV. The detection system will be comprised of High Purity Germanium and BaF2 detectors, facing each other, for low background Doppler Broadening (DB) measurements. The target cell is designed to allow a combined measurement of sample conductivity and DB, with the flexibility to add more detection options in the future. The compact PAL spectrometer includes two fast scintillation detectors read by a fast digitizer (DRS4), with a sampling rate of 5.12 GS/s. A dedicated software package was developed to emulate analogue data acquisition. Lifetime measurements were performed using a ∼25 µCi 22Na sou...

Details

ISSN :
0094243X
Database :
OpenAIRE
Journal :
INTERNATIONAL CONFERENCE ON SCIENCE AND APPLIED SCIENCE (ICSAS) 2019
Accession number :
edsair.doi.dedup.....8d630c0bb7431fb526a27433879a8192
Full Text :
https://doi.org/10.1063/1.5135841