Back to Search
Start Over
Standardized uptake value and radiological density attenuation as predictive and prognostic factors in patients with solitary pulmonary nodules: our experience on 1,592 patients
- Source :
- Journal of Thoracic Disease. 9:2551-2559
- Publication Year :
- 2017
- Publisher :
- AME Publishing Company, 2017.
-
Abstract
- Background: Multislice computed tomography (MSCT) increased detection of solitary pulmonary nodules (SPNs), changing the management based on radiological and clinical factors. When 18-fluorine fluorodeoxyglucose positron emission tomography combined with computed tomography ( 18 F-FDG-PET/CT) was considered for the evaluation of nodules, the maximum standardized uptake value (SUVmax) more than 2.5 is used frequently as a cut off for malignancy. The purpose of this study is to evaluate SUVmax PET/CT and pulmonary attenuation patterns at MSCT in patients with SPN according to morphological and pathological characteristics of the lesion. Methods: A retrospective study on 1,592 SPN patients was carried out following approval by the Italian Registry of VATS Lobectomies. Results: All patients underwent VATS lobectomy. On histologic examination, 98.1% had primary or second metachronous primary lung cancers. In addition, 10.7% presented occult lymph node metastases (pN1 or pN2) on histological examination. Nodule attenuation on CT was associated with the histology of the lesion (p= 0.030); in particular, pure ground glass opacities (pGGOs) and partially solid nodules were related to adenocarcinomatous histotypes. Conversely, a significant relationship between SUVmax and age, nodule size, pathological node status (pN) was found (P=0.007, P=0.000 and P=0.002 respectively). Conclusions: Nodule attenuation can predict the histology of the lesion whereas SUVmax may relate to the propensity to lymph node metastases.
- Subjects :
- Lung adenocarcinoma
Pulmonary and Respiratory Medicine
medicine.medical_specialty
VATS lobectomy
Standardized uptake value
Malignancy
Ground-glass opacity
NO
030218 nuclear medicine & medical imaging
Maximum standardized uptake value
03 medical and health sciences
0302 clinical medicine
ground glass opacities
Solitary pulmonary nodule (SPN)
maximum standardized uptake value
lymph node metastases
lung adenocarcinoma
Lymph node metastase
medicine
Ground glass opacities
Lymph node metastases
Lung cancer
Lymph node
business.industry
Ground glass opacitie
Nodule (medicine)
medicine.disease
Primary tumor
medicine.anatomical_structure
030220 oncology & carcinogenesis
Original Article
Radiology
medicine.symptom
business
Subjects
Details
- ISSN :
- 20776624 and 20721439
- Volume :
- 9
- Database :
- OpenAIRE
- Journal :
- Journal of Thoracic Disease
- Accession number :
- edsair.doi.dedup.....8efdb98b26ec22b6343f6f76bc8bf2ea
- Full Text :
- https://doi.org/10.21037/jtd.2017.06.124